Kyocera ECOSYS P3060dn Service Manual page 95

Hide thumbs Also See for ECOSYS P3060dn:
Table of Contents

Advertisement

Code
Contents
F4DX
Abnormality detecting in the Entity Manage-
ment Department
F4EX
F4FX
Abnormality detecting in the JOB Management
Department
F52X
Abnormality detecting in a JOB execution part
F53X
F55X
F56X
F57X
F61X
Abnormality detecting in a report creation part
F63X
Abnormality detecting in a device control sec-
tion
F68X
Abnormality detecting in a storage device con-
trol section
F90X
Abnormality detecting in the extension applica-
tion service part
F93X
Abnormality detecting in the extension applica-
tion management part
Verification procedure & check point
(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
"(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
(1) U021 Controller backup initialization is carried out and an operation check is
performed.
(2) Exchange a Main board and perform an operation check.
(3) Get USBLOG and contact service headquarters.
Remarks
Since the USB log immediately after
occurrence is needed for analysis,
please give me cooperation of acquisi-
tion.
Since the USB log immediately after
occurrence is needed for analysis,
please give me cooperation of acquisi-
tion.
Since the USB log immediately after
occurrence is needed for analysis,
please give me cooperation of acquisi-
tion.
* F684 is the overwrite error at the time
of an HDD security kit.
Since the USB log at the time of occur-
rence is needed for analysis, please
give me cooperation of acquisition.
Since the USB log at the time of occur-
rence is needed for analysis, please
give me cooperation of acquisition.
1-4-27
2T6/2T7/2T8/2T9
ECOSYS P3060dn/P3055dn/P3050dn/P3045dn
[Main PWB]
There is no hard components that can be checked in the
field.
[Controller failure]
Turn power on and off to clear.
USB log is required for investigation.