Connections
9.8 PROFINET
9.8.4
Example PROFINET CBA configuration
The following figure shows a typical system configuration with PROFINET CBA.
Figure 9-7
Example PROFINET CBA configuration
Station name
Central
Unit01
Unit02
Unit03
90
Module type
NCU 730.2 PN
PCU 50.3
MPP 483 IE
NCU 730.2 PN
CPU 319-3 PN/DP
CPU 317-2 PN/DP
Interface
X120
Port 1
X500
X20 DHCP server
X120
Port 1
PN P1
PN P1
Manual, 07/2007, 6FC5397-0AP10-2BA0
IP address
192.168.200.1
192.168.200.2
192.168.200.5
192.168.200.50...
192.168.200.11
192.168.200.12
192.168.200.22
192.168.200.32
NCU