ATEX Approvals
FM14ATEX0014X
FM14ATEX0015X
Intrinsically Safe
II 1G Ex ia IIC T6...T4 Ga
II 1D Ex ia IIIC T96°C Da
II 3G Ex ic IIC T6...T4 Gc
Dust Ignitionproof
II 2D Ex tb IIIC T96°C Db
II 3D Ex tc IIIC T96°C Dc
IECEx Approvals
IECEx FMG 14.0007X
Intrinsically Safe
Ex ia IIC T6...T4 Ga
Ex ia IIIC T96°C Da
Ex ic IIC T6...T4 Gc
Dust Ignitionproof
Ex tb IIIC T96°C Db
Ex tc IIIC T96°C Dc
Operating Ranges
Temp:
Voltage: 9 to 32V DC
Pressure: 150 psig (1.03MPa)
Current: 18.3 mA (Max)
Notes Related to Explosionproof Rating
1) "DO NOT OPEN EVEN WHEN ISOLATED WHEN EXPLOSIVE ATMOSPHERES ARE
Notes Related to Intrinsic Safety
1) "INSTALL Per ES-776"
2) "Supply Connection Wiring Rated for 10ºC Above Max Ambient"
3) "PERMANENTLY MARK THE PROTECTION TYPE CHOSEN. ONCE THE TYPE HAS
BEEN MARKED, IT CAN NOT BE CHANGED"
Model Code:
"SVI-abcdefgh"
Serial Number:
"SN-nnyywwnnnn"
Copyright 2016. This document and all information herein is the property of Dresser Inc.
© 2017 General Electric Company. All rights reserved
-40°C ≤ Ta ≤ 85°C
PRESENT"
(see section 3 above for explanation)
Flame Proof
II 2G Ex d mb IIC T6...T4 Gb
Flame Proof
Ex d mb IIC T6...T4 Gb
.
Masoneilan SVI FF Positioner Quick Start Guide =| 25
GE Oil & Gas
Temperature Classification
T4 Ta = -40°C to 85°C
T5 Ta = -40°C to 75°C
T6 Ta = -40°C to 60°C
Ingress Protection
IP66
Temperature Classification
T4 Ta = -40°C to 85°C
T5 Ta = -40°C to 75°C
T6 Ta = -40°C to 60°C
Ingress Protection
IP66
ES-776 Rev L