E50 instructions :Layout 1
Handset to hose assembly
1
Ensuring the hose washer is in the correct position, connect the hose to the handset, taking
care not to overtighten and place into position within the handset holder.

Thermal trip

The Thermal trip cut out will operate with extreme water temperatures. The 'Overheat' LED will illuminate. Power to the heater
element(s) is cut when the trip operates. Power restores when the water is cold enough to reset the trip. Unless the temperature dial
is adjusted, or other cause of high temperature is eliminated, the element(s) will continue to cycle on/off and the temperature will
cycle hot and cold. Temperature reduces, but the heat setting knob remains at its set position.

Low flow

If the 'Low flow' LED is illuminated, the supply water pressure is too low. The heating elements will automatically switch off and the
unit will run cold. Power will automatically be restored to the heating elements, once the sufficient water supply pressure is available.