Operating Environment; Mechanical Specifications - Siemens RUGGEDCOM RS969 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS969:
Table of Contents

Advertisement

RUGGEDCOM RS969
Installation Guide
Mode
Connector
MM
LC
SM
LC
SM
LC
d
Typical.
Section 4.5

Operating Environment

Parameter
Ambient Operating Temperature
Ambient Relative Humidity
Ambient Storage Temperature
IP Rating
Operating Altitude
Section 4.6

Mechanical Specifications

Parameter
Dimensions
Weight
Ingress Protection
Enclosure
Operating Environment
Cable
d
Tx λ (nm)
Type (µm)
50/125
850
62.5/125
8/125
1310
9/125
8/125
1310
9/125
Range
-40 to 85° C (-40 to 185° F)
5% to 95%
-40 to 85° C (-40 to 185° F)
IP67
0 to 15240 m (0 to 50000 ft)
Value
Refer to
Chapter 5, Dimension Drawings
2.5 kg (5.5 lb)
IP66, IP677
Cast Aluminum
Tx Pwr
Rx
(dBm)
Sensitivity
(Min/Max)
(dBm)
-9.5/-4
-20
-9.5/-3
-22
-7/3
-26
Comments
Ambient Temperature as measured from a 30 cm (12 in.) radius
surrounding the center of the RS969 enclosure.
Non-condensing
Over temperature range of -40 to 85° C (-40 to 185° F)
Technical Specifications
Rx
Typical
Saturation
Distance
(dBm)
(km)
0
0.5
-3
10
-3
25
Chapter 4
Power
Budget (dB)
14
17
19
25

Advertisement

Table of Contents
loading