Siemens RUGGEDCOM RS969 Installation Manual
Hide thumbs Also See for RUGGEDCOM RS969:

Advertisement

Quick Links

RUGGEDCOM RS969
Installation Guide
6/2014
RC1038-EN-02
Preface
Introduction
Installing the Device
Communication Ports
Technical Specifications
Dimension Drawings
Accessories
Certification
1
2
3
4
5
6
7

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RS969

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RS969 Communication Ports Technical Specifications Dimension Drawings Installation Guide Accessories Certification 6/2014 RC1038-EN-02...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM RS969 Installation Guide Table of Contents Table of Contents Preface ........................ Alerts ..............................v Related Documents ..........................v Accessing Documentation ........................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ......................1.1 Feature Highlights ........................1 1.2 Ports, Controls and Indicator LEDs ....................3 Chapter 2 Installing the Device ....................
  • Page 4 RUGGEDCOM RS969 Table of Contents Installation Guide 4.4 Fiber Optic Ethernet Port Specifications ..................24 4.4.1 Fast Ethernet Optical Specifications .................. 24 4.4.2 Gigabit Ethernet Optical Specifications ................24 4.5 Operating Environment ....................... 25 4.6 Mechanical Specifications ......................25 Chapter 5 Dimension Drawings ..................
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RS969. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, please contact Siemens Customer Support through any of the following methods: • Online Visit http://www.siemens.com/automation/support-request...
  • Page 7: Introduction

    Introduction Introduction The RUGGEDCOM RS969 is an industrially hardened, fully managed Ethernet switch providing dual fiber optical Fast Ethernet or Gigabit ports and eight Fast Ethernet copper ports in an IP65/IP67 rated package for protection against low pressure jets of water (IP65) or temporary immersion in water (IP67).
  • Page 8 Chapter 1 RUGGEDCOM RS969 Introduction Installation Guide • Meets IEEE 1613 (electric utility substations) • Exceeds IEC 61850-3 (electric utility substations) • Exceeds IEEE 61800-3 (variable speed drive systems) • Exceeds IEC 61000-6-2 (generic industrial environment) • Exceeds NEMA TS-2 (traffic control equipment) •...
  • Page 9: Ports, Controls And Indicator Leds

    RUGGEDCOM RS969 Chapter 1 Installation Guide Introduction Section 1.2 Ports, Controls and Indicator LEDs Figure 1: RS969 with M12 D-Core and Mini-Change Power Connector 1. Fast Ethernet Ports - M12 D-Code Connectors 2. LED Indicators 3. Console Port - RS232 4.
  • Page 10 Chapter 1 RUGGEDCOM RS969 Introduction Installation Guide Figure 2: RS969 with RJ45 and M23 Power Connector 1. Fast Ethernet Ports - RJ45 Connectors 2. LED Indicators 3. Console Port - RS232 4. Failsafe Output Relay 5. Power Supply - M23 Connector 6.
  • Page 11: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 12: Connecting Power

    Chapter 2 RUGGEDCOM RS969 Installing the Device Installation Guide Figure 3: Panel Mounting (Typical) 1. Flange Install the supplied screws to secure the flanges to the panel. Section 2.2 Connecting Power The following sections describe how to connect power to the device: •...
  • Page 13: Power Supply Input Connectors Description

    RUGGEDCOM RS969 Chapter 2 Installation Guide Installing the Device Section 2.2.1 Power Supply Input Connectors Description The RS969 family has 2 different power supply input connectors: a Mini A-coded male connector or M23 A-code male connector shown in the figures below. The Mini power connector only has 4 terminals, so only one power supply source is allowed to connect to the RS969 with the Mini power connector.
  • Page 14 Chapter 2 RUGGEDCOM RS969 Installing the Device Installation Guide Figure 5: M23 Power Supply Connector Terminal # Description Usage PS1 Live / + PS1 Live / + is connected to the positive (+) terminal if the power source is DC or to the (Live) terminal if the power source is AC.
  • Page 15 RUGGEDCOM RS969 Chapter 2 Installation Guide Installing the Device Figure 6: Surge Ground / Chassis Ground Connection NOTE • Equipment must be installed according to the applicable country wiring codes. • All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where users require the inputs to be isolated from ground, remove the ground braid between Surge and Chassis Ground.
  • Page 16: Single High Ac Power Supply Wiring Examples

    Chapter 2 RUGGEDCOM RS969 Installing the Device Installation Guide Section 2.2.2 Single High AC Power Supply Wiring Examples Figure 7: AC Power Supply Wiring Example (M23 Connector) Figure 8: AC Power Supply Wiring Example (Mini-Change Connector) NOTE • 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be installed.
  • Page 17: Single Low Dc Power Supply Wiring Examples

    RUGGEDCOM RS969 Chapter 2 Installation Guide Installing the Device Section 2.2.3 Single Low DC Power Supply Wiring Examples Figure 9: DC Power Supply Wiring Example (Mini-Change Connector) Figure 10: DC Power Supply Wiring Example (M23 Connector) NOTE • 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be installed.
  • Page 18: Dual High Ac/Dc Power Supplies

    Chapter 2 RUGGEDCOM RS969 Installing the Device Installation Guide Section 2.2.4 Dual High AC/DC Power Supplies Figure 11: AC and AC Power Supply Wiring Example Figure 12: DC and DC Power Supply Wiring Example Dual High AC/DC Power Supplies...
  • Page 19: Connecting The Failsafe Alarm Relay

    RUGGEDCOM RS969 Chapter 2 Installation Guide Installing the Device Figure 13: DC and AC Power Supply Wiring Example NOTE • 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be installed. • A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
  • Page 20: Connecting To The Device

    Chapter 2 RUGGEDCOM RS969 Installing the Device Installation Guide Figure 14: Failsafe Alarm Relay Wiring Section 2.4 Connecting to the Device The following describes the various methods for accessing the ROS console and Web interfaces on the device. For more detailed instructions, refer to the ROS User Guide for the RS969.
  • Page 21 RUGGEDCOM RS969 Chapter 2 Installation Guide Installing the Device Name Description Male Female Male Female Reserved (Do Not Connect) Transmit Data (from DTE) Receive Data (from DTE) Reserved (Do Not Connect) Common Ground Reserved (Do Not Connect) Reserved (Do Not Connect) Reserved (Do Not Connect) —...
  • Page 22: Cabling Recommendations

    Section 2.5.1 Protection On Twisted-Pair Data Ports Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 23 RUGGEDCOM RS969 Chapter 2 Installation Guide Installing the Device The RS969 Industrial Ethernet Switch is manufactured and tested to IP67 standards. With an IP67 rating a product will be "dust tight" and remain completely sealed when immersed in water to a depth of 1 meter for 1 hour.
  • Page 24 RUGGEDCOM RS969 Chapter 2 Installation Guide Installing the Device Ingress Protection...
  • Page 25: Communication Ports

    RUGGEDCOM RS969 Chapter 3 Installation Guide Communication Ports Communication Ports The RS969 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through ROS. For more information on how to access the factory data file, refer to the ROS User Guide for the RS969.
  • Page 26: Copper Ethernet Ports

    Chapter 3 RUGGEDCOM RS969 Communication Ports Installation Guide Figure 18: Port Assignment (RJ45 Connectors Shown) 1. RJ45 Copper Ethernet Ports 2. Fibre Optic Ethernet Ports The following sections describe the available ports: • Section 3.1, “Copper Ethernet Ports” • Section 3.2, “Fiber Optic Ethernet Ports”...
  • Page 27: Fiber Optic Ethernet Ports

    RUGGEDCOM RS969 Chapter 3 Installation Guide Communication Ports Each port features a Speed and Link LED that indicates the state of the port. State Description Speed Yellow The port is operating at 100 Mbps The port is operating at 10 Mbps...
  • Page 28 Chapter 3 RUGGEDCOM RS969 Communication Ports Installation Guide Figure 21: LC Port 1. Tx Connector 2. Rx Connector For specifications on the available fiber optic Ethernet ports, refer to Section 4.4, “Fiber Optic Ethernet Port Specifications”. Fiber Optic Ethernet Ports...
  • Page 29: Technical Specifications

    RUGGEDCOM RS969 Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.3, “Copper Data Port Specifications”...
  • Page 30: Copper Data Port Specifications

    Section 4.4 Fiber Optic Ethernet Port Specifications For maximum flexibility, Siemens offers a number of different transceiver choices for fiber optical communications. The following sections detail fiber optic specifications based on the order code / transceiver selected at time of ordering.
  • Page 31: Operating Environment

    RUGGEDCOM RS969 Chapter 4 Installation Guide Technical Specifications Tx Pwr Typical Cable Power Mode Connector Tx λ (nm) (dBm) Sensitivity Saturation Distance Type (µm) Budget (dB) (Min/Max) (dBm) (dBm) (km) 50/125 -9.5/-4 62.5/125 8/125 1310 -9.5/-3 9/125 8/125 1310 -7/3 9/125 Typical.
  • Page 32 RUGGEDCOM RS969 Chapter 4 Installation Guide Technical Specifications Mechanical Specifications...
  • Page 33: Dimension Drawings

    RUGGEDCOM RS969 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in inches, unless otherwise stated. Figure 22: M12 Connectors...
  • Page 34 Chapter 5 RUGGEDCOM RS969 Dimension Drawings Installation Guide Figure 23: RJ45 Connectors...
  • Page 35: Accessories

    RUGGEDCOM RS969 Chapter 6 Installation Guide Accessories Accessories This chapter includes the following information: • Section 6.1, “Power (1/unit)” • Section 6.2, “Console (1/unit)” • Section 6.3, “Failsafe (1/unit)” • Section 6.4, “Ethernet (8/unit)” • Section 6.5, “LC Fiber Optic (2/unit)”...
  • Page 36: Console (1/Unit)

    Chapter 6 RUGGEDCOM RS969 Accessories Installation Guide Mini Power Mating Cordset Description: MINI-Change 4pin female connector; 4/16AWG, rubber P/N 99-43-0183-001 Figure 25: Mini Power Mating Cordset Section 6.2 Console (1/unit) M12 Console Port Mating Cable Description: M12 8pin A-code male to DB9 female;...
  • Page 37: Failsafe (1/Unit)

    RUGGEDCOM RS969 Chapter 6 Installation Guide Accessories M12 Console Port Mating Connector Description: M12-straight plug, 8 pole, A-coded, IP67 rated P/N 99-60-0002 Figure 27: M12 Console Port Mating Connector Section 6.3 Failsafe (1/unit) M12 FailSafe Port Mating Cable Description: M12 4pole A-coded; unshielded, PUR...
  • Page 38: Ethernet (8/Unit)

    Chapter 6 RUGGEDCOM RS969 Accessories Installation Guide M12 FailSafe Port Mating Connector Description: M12-straight plug, 4 pole, A-coded, IP67 rated P/N 99-60-0009 Figure 29: M12 FailSafe Port Mating Connector Section 6.4 Ethernet (8/unit) M12 D-code Ethernet Port Mating Cable Description: M12 D-code to RJ45; patch cable,...
  • Page 39 RUGGEDCOM RS969 Chapter 6 Installation Guide Accessories M12 D-code Ethernet Port Mating Connector Description: M12-straight plug, 4 pole, D-coded, IP67 rated P/N 99-60-0008 Figure 31: M12 D-code Ethernet Port Mating Connector IP67 RJ45 Ethernet Port Mating Cable Description: IP67 RJ45 plug to RJ45; Category 5e shielded patch cable, 3.1m...
  • Page 40: Lc Fiber Optic (2/Unit)

    Chapter 6 RUGGEDCOM RS969 Accessories Installation Guide IP67 RJ45 Ethernet Port Mating Connector Description: IP67 RJ45 plug, field attachable P/N 30-50-0019 Figure 33: IP67 RJ45 Ethernet Port Mating Connector Section 6.5 LC Fiber Optic (2/unit) LC Port Mating Connector Description: IP67 Multimode LC plug...
  • Page 41 RUGGEDCOM RS969 Chapter 6 Installation Guide Accessories Description: IP67 Singlemode LC plug P/N 99-60-0002-001 Figure 35: LC Port Mating Connector LC Port Mating Connector Description: Multimode IP67 LC plug to LC connector, P/N 99-43-0056-001 Figure 36: LC Port Mating Connector...
  • Page 42 RUGGEDCOM RS969 Chapter 6 Installation Guide Accessories LC Fiber Optic (2/unit)
  • Page 43: Certification

    RUGGEDCOM RS969 Chapter 7 Installation Guide Certification Certification The RS969 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 7.1, “Agency Approvals” • Section 7.2, “FCC Compliance”...
  • Page 44: Emi And Environmental Type Tests

    Chapter 7 RUGGEDCOM RS969 Certification Installation Guide Section 7.4 EMI and Environmental Type Tests This section contains the following information: • Section 7.4.1, “IEC 61850-3 Type Tests” • Section 7.4.2, “IEEE 1613 Type Tests” • Section 7.4.3, “IEC Environmental Type Tests”...
  • Page 45: Ieee 1613 Type Tests

    RUGGEDCOM RS969 Chapter 7 Installation Guide Certification Severity Test Description Test Levels Levels IEC 61000-4-17 Ripple on D.C. D.C. Power ports Power Supply IEC 60255-5 Dielectric Strength Signal ports 2 kVAC (Fail-Safe Relay output) D.C. Power ports 1.5kVDC A.C. Power ports...
  • Page 46: Iec Environmental Type Tests

    Chapter 7 RUGGEDCOM RS969 Certification Installation Guide Section 7.4.3 IEC Environmental Type Tests Table: Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold Temperature Test Ad -40 deg. C, 16 Hours IEC 60068-2-2 Dry Heat Test Bd +85 deg.

Table of Contents