GF Signet 2551 Operating Instructions Manual

GF Signet 2551 Operating Instructions Manual

Blind magmeter flow sensor
Hide thumbs Also See for Signet 2551:

Advertisement

Signet 2551 Blind Magmeter
*3-2552.090*
3-2551.090
Rev. P 04/16
• English
• Deutsch
• Français
• Español
• Italiano
• Português
Description
The Signet 2551 Magmeter is an insertion-style magnetic fl ow sensor. The patented
sensor design is available in a variety of corrosion-resistant materials to provide long-
term reliability and minimal maintenance costs. Wetted material combinations include
PP/316 SS, PVDF/Hastelloy-C and PVDF/Titanium. The 2551 installs quickly and
securely into a wide selection of fl ow fi ttings to deliver accurate fl ow measurement in
pipe sizes ranging from DN15 to DN900 (½ in. to 36 in.).
Signet 2551 Magmeters are available with a frequency output or Digital (S
for use with the Signet 9900-1BC Batch Controller, 8900 Multi-Parameter Controller
or 9900 Transmitter, or with a 4 to 20 mA output for a direct input to a PLC, SCADA or
telemetry system.
All 2551 Magmeters feature empty pipe detection and LED-assisted diagnostics.
The Signet 3-0252 Confi guration Tool set-up tool is available to customize every
performance feature in the 2551 to adapt it to the specifi c application requirements.

Table of Contents

Quick Start ..............................................................................................2
Warranty Information ...............................................................................2
Product Registration ................................................................................2
Safety Information ...................................................................................2
Chemical Compatibility ............................................................................2
Specifi cations ..........................................................................................3
Dimensions ..............................................................................................3
Installation: Pipe Fittings..........................................................................4
Selecting a Location ................................................................................4
Hardware Confi guration...........................................................................5
General Installation and Grounding Tips .................................................6
Wiring with 4 to 20 mA Loop ....................................................................6
Calibration and Software Confi guration ...................................................7
Calibration Data .......................................................................................8
Maintenance and Troubleshooting ........................................................10
Ordering Information.............................................................................. 11

Operating Instructions

L) Output .........................................7
3
English
3
L) output

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Signet 2551 and is the answer not in the manual?

Questions and answers

Summary of Contents for GF Signet 2551

  • Page 1: Table Of Contents

    Rev. P 04/16 Operating Instructions Description The Signet 2551 Magmeter is an insertion-style magnetic fl ow sensor. The patented sensor design is available in a variety of corrosion-resistant materials to provide long- term reliability and minimal maintenance costs. Wetted material combinations include PP/316 SS, PVDF/Hastelloy-C and PVDF/Titanium.
  • Page 2: Quick Start

    Service Form and goods must be Do not alter product construction. returned to your local GF Sales offi ce or distributor. Disconnect power before attempting any service or wiring. Product returned without a Service Form may not be warranty replaced or repaired.
  • Page 3: Specifi Cations

    General This manual contains the general installation, wiring and Pipe size range ....DN15 to DN 900 (0.5 in. to 36 in.) calibration data for the Signet 2551-XX-11 Magmeter with Flow Range Frequency or Digital (S L) data output, and for the Signet Minimum .....0.05 m/s (0.15 ft/s)
  • Page 4: Dimensions

    Wafers 90° 90° DN 15 mm to 50 mm PP or PVDF 180° +GF+ Vertical fl ow is ok if the pipe Vertical flow is OK if the pipe remains full at remains full at all times. 2551 Blind Magmeter...
  • Page 5: Hardware Confi Guration

    Hardware Confi guration Whether using the 2551-XX-11 (with frequency or Digital The user must connect output cables to JP2 is for factory use only. this 4-terminal block. L) output) or the 2551-XX-12 (with 4 to 20 mA output), the MAKE NO CONNECTIONS. wiring terminals located on the inside of the yellow cover are identical.
  • Page 6: General Installation And Grounding Tips

    General Installation and Grounding Tips Sensor conditioning The Magmeter output signal may be unstable immediately after installation. Allowing the sensor to soak in a full pipe (or in any container of water) for 24 hours will stabilize the performance. • Very low conductivity fl uids may require a longer conditioning period. (The Magmeter will not operate properly in fl uids where the conductivity is less than 20 μS/cm.) Grounding The 2551 Magmeter is unaffected by moderate levels of electrical noise.
  • Page 7: Calibration And Software Confi Guration

    Wiring with Frequency or Digital (S L) Output Frequency output (Compatible with all POWERED Signet Flow instruments.) Blue Jumper ON = FREQ OUT • When the blue jumper illustrated here is placed over both pins, the 2551-XX-11 Frequency outputs an open collector frequency signal that can be connected to any powered Signet fl...
  • Page 8: Calibration Data

    Calibration Data: K-Factors and Full Scale Current Values Plastic Installation Fittings: PVC Tees and Saddles Plastic Installation Fittings for Metric Pipes: Polypropylene True Union Tees and Wafers PVDF True Union Tees, PVC True Union Tees Pipe Pipe Fitting K-Factor K-Factor 20 mA= 20 mA= Fitting...
  • Page 9 Calibration Data: K-Factors and Full Scale Current Values Metal Installation Fittings: Metal Installation Fittings: Carbon Steel Tees and Weld-o-Lets Bronze and Copper Tees and Brazolets Stainless Steel Tees and Weld-o-Lets, Galvanized Iron Tees Pipe Pipe Fitting K-Factor K-Factor 20 mA= 20 mA= Fitting K-Factor...
  • Page 10: Maintenance And Troubleshooting

    Maintenance The 2551 Magmeter requires very little maintenance. There are no user-serviceable components in the Magmeter. • If the fl uid contains deposits and solids that may coat the electrodes, a regular cleaning schedule is recommended. • Do not use abrasive materials on the metal electrodes. Clean with soft cloth and mild detergent only. •...
  • Page 11: Ordering Information

    Troubleshooting Troubleshooting with the RED and BLUE LEDs Both Off: The power is off or the sensor is not connected. Solid Blue: The power is on, the pipe is full, but there is no fl ow in the pipe. Blinking Blue: Normal operation, blink rate is proportional to the fl...
  • Page 12 Ordering Information 4 to 20 mA output Mfr. Part No. Code Description 3-2551-P0-12 159 001 110 DN15 to DN100 (½ to 4 in.), Polypropylene and 316L SS 3-2551-T0-12 159 001 113 DN15 to DN100 (½ to 4 in.), PVDF and Titanium 3-2551-V0-12 159 001 259 DN15 to DN100 (½...