Setting Safety Shutdown Temperature; Setting The Sunrise And Sunset Period - Gavita Master EL2 User Manual

Table of Contents

Advertisement

Press "enter", the controller menu will open
Press the arrow keys
The auto-dim temperature screen opens
Press the arrow keys
Press "enter" to confirm.
Once the auto-dim temperature is reached, the controller will automatically
start dimming the lights. No auto-dim will occur if the shutdown temperature
is set at the auto-dim temperature.
Note: the auto-dim will stay on until half a degree Celsius / 0,9 degrees
Fahrenheit under the set temperature.

Setting safety shutdown temperature

6.4.2.
Note: The default shutdown temperature is set at 35
Note: The safety shutdown temperature of the controller cannot be set lower
than the auto-dim temperature.
Warning! Always set the shutdown temperature so it does not accidentally
deactivate the lights.
Warning! After a shutdown, a manual reset is required.
Press "enter", the controller menu will open
Press the arrow keys
The "Shutdown temperature" screen opens
Press the arrow keys
Press "enter" to confirm.
Once the shutdown temperature is reached (20), the controller will
automatically shut down all the lights and all the equipment connected to the
ECMs. The A-NC and A-NO alarm contacts will also switch (see paragraph 4.5).
6.5.

Setting the sunrise and sunset period

To allow crops to adjust to either a lights-on or lights-off period, a sunrise
and sunset period may be set. During this period, the light intensity increases
from 50 percent to up to the desired intensity.
Press "enter", the controller menu will open
Press the arrow keys
The "Set ramp time" screen opens
Press the arrow keys
minutes. 0 minutes indicates no ramp up/down time
Press "enter" to confirm your choice.
to locate "Auto-Dim Temp" and press "enter".
to increase or decrease the temperature.
to locate "Shutdown Temp" and press "enter".
to increase or decrease the temperature.
to locate "Sunrise/sunset" and press "enter".
to increase the ramp up/down time to up to 30
34
C /95
F.