Programmable functions
STF ROBUS 600-1000 – Rev00
Firmware: RF02
using the Oview programmer

Advertisement

loading
Need help?

Need help?

Do you have a question about the Robus 600 and is the answer not in the manual?

Questions and answers

Alessandro Canton
February 1, 2025

Aumentare la forza di chiusura e apertura

1 comments:
Mr. Anderson
February 10, 2025

The Nice Robus 600's opening and closing force can be increased by adjusting the motor's torque settings. This is typically done through the control unit by modifying the force parameters. Refer to the programming section of the manual to access and adjust the torque settings to a higher value as needed. Ensure that the adjustment stays within safe operational limits to avoid damage or safety issues.

This answer is automatically generated

Summary of Contents for Nice Robus 600

  • Page 1 Robus 600/1000 Programmable functions using the Oview programmer STF ROBUS 600-1000 – Rev00 Firmware: RF02...
  • Page 2: Common Functions

    Two types of password can be programmed on the devices (including Oview). - the user password, comprising maximum 6 alphanumeric characters. Caution! – Do not use uppercase letters. - the installer password, comprising maximum 6 alphanumeric characters. Caution! – Do not use uppercase letters. 2 – Robus 600-1000...
  • Page 3: Control Unit Functions

    If the function is not active (OFF) the Control unit operation mode is “semiautomatic”. pause time This parameter is expressed in seconds and can be set with a value from 0 to 250 sec.; the factory setting is 30 sec. This func- Robus 600-1000 – 3...
  • Page 4 • manual force level This parameter can be set with a value from 10% to 100%; the factory setting is 100%. The function enables control of the force absorbed by the motor during execution of a manoeuvre. 4 – Robus 600-1000...
  • Page 5 Bluebus output (devices) and all leds, with the exception of the Bluebus led, which flashes at a slower inter- val. Note – When the control unit receives a command, it automatically restores normal operation of the automation, and no longer in energy saving mode. Robus 600-1000 – 5...
  • Page 6: Advanced Parameters

    “step step” and oper- figuration” > “step step” > operating ating sequence “open- stop - close - open”. mode...) When this command is sent, the control unit activates the application to complete the next 6 – Robus 600-1000...
  • Page 7 > “opening” > operating mo de...) ning manoeuvre until the position is reached as set in the function “partial open 3”(Control unit functions > installation > positions > partial open 3). Input configured as normally open. Robus 600-1000 – 7...
  • Page 8 Note – This apartment block step step com- mand is used for apartment blocks and in gen- eral envisages programming of all apartment block transmitters with a single “apartment block step step” key. Input configured as normally open. 8 – Robus 600-1000...
  • Page 9 When this command is sent, the control unit selecting in Table 1-D (“command con fig- activates the slave (secondary) leaf of the appli- uration” > “closing” > operating mo de...) cation to complete a Closing manoeuvre. Input configured as normally open. Robus 600-1000 – 9...
  • Page 10 2 seconds, the control unit activates a “partial open 1” command (input configuration > Table 1). Hold-to-run The Opening or Closing manoeuvre is executed exclusively if the transmitter key is held down (hold-to-run). 10 – Robus 600-1000...
  • Page 11 In this command category the user can select one of the operating modes specified in Table 1-D. TABLE 1-D: COMMAND CONFIGURATION OPERATING MODE DESCRIPTION Close - stop - close Operating mode set in factory (Input 3 - “close” comma - nd). This executes the above sequence. Robus 600-1000 – 11...
  • Page 12 When the control unit receives the command, it stops the Closing manoeuvre in progress and activates the application to perform a brief inversion in the opposite direction (Opening). Caution! – During execution of the Opening manoeuvre, this command is ignored. 12 – Robus 600-1000...
  • Page 13 In this command category the user can select one of the operating modes specified in Table 1-L. TABLE 1-L: COMMAND CONFIGURATION OPERATING MODE DESCRIPTION When this type of function is set, when the control unit re - ceives the command, it stops the Opening manoeuvre in progress immediately. Robus 600-1000 – 13...
  • Page 14 Operating mode set in factory. When this type of function is set, when the control unit receives the command, it stops the Closing manoeuvre in progress immediately and activates the application to perform a total inversion in the opposite direc- tion (Opening). 14 – Robus 600-1000...
  • Page 15 WARNING – If this channel is not free on the control unit receiver, as previously memorised with a command, the con- trol unit activates exclusively the programmed output when the channel is activated with the transmitter, ignoring the com- mand to the motor. Robus 600-1000 – 15...
  • Page 16 = number of manoeuvres over 100%. flashing light This function enables the flashing light to indicate execution of a manoeuvre in progress with flashes at regular intervals (o.5 sec ON, 0.5 sec OFF). 16 – Robus 600-1000...
  • Page 17 Output active 24Vdc / max 4 W Robus 600-1000 – 17...
  • Page 18 Indicates when motor 1 reaches the maximum opening position. Limit switch on closing Indicates when motor 1 reaches the maximum closing position. MANOEUVRE THRESHOLD: Indicates the operating status of the manoeuvre limiter, expressed in levels: Level 1: OK; 18 – Robus 600-1000...
  • Page 19 Indicates the timer for shutoff of the courtesy light. Pause time Indicates the timer for counting the pause time between one manoeuvre and the next. Temperature Indicates the temperature of the motor, measured by the control unit. Robus 600-1000 – 19...
  • Page 20 Indicates whether the control photocell is present, the relative oper- ating status and the correct memorisation in the control unit. CMD 4 Indicates whether the control photocell is present, the relative oper- ating status and the correct memorisation in the control unit. 20 – Robus 600-1000...
  • Page 21 This parameter type is ON / OFF; the factory setting is “OFF”. This function enables deletion of the “partial count” value; this is required after performing maintenance on the automation. Robus 600-1000 – 21...
  • Page 22: Advanced Functions

    This function enables the firmware of a control unit to be updated with another compatible version, without the obligation to change the board. To update, proceed as follows: 01. Download the firmware update file (the software update is available at the site internet www.nice-service.com); 02. In “Advanced Functions” select “Update firmware”;...

This manual is also suitable for:

Robus 1000