Therma-Stor Ultra Aire XT105H Owner's Manual

Therma-Stor Ultra Aire XT105H Owner's Manual

Hide thumbs Also See for Ultra Aire XT105H:

Advertisement

INSTALLER'S & OWNER'S MANUAL
HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
XT105H
Dehumidification
The highly efficient Ultra-Aire XT whole house ventilating
dehumidifier utilizes refrigeration to cool the incoming air stream
below its dew point. This cooled and drier air is used to pre-cool
the incoming air stream resulting in a significant increase in overall
efficiency. After the pre-cooling stage, the processed air is reheated
by passing through the condenser coil. The heat removed by the
evaporator coil is returned to the air stream, resulting in an overall
temperature increase of the air leaving the unit.
The Ultra-Aire XT's are controlled by 24 volt remote wired controls.
A variety of controls are available for various applications.
P/N 4032240 (XT105H)
P/N 4031070 (XT155H)
P/N 4031560 (XT205H) • Serial No.________________________ Install Date:___________
Sold by:
XT155H
Fresh Air Ventilation
Optional fresh outdoor air may be ducted to the unit via a six inch
round duct. This provides fresh air to dilute pollutants and maintain
high oxygen content in the air. The amount of fresh air ventilation
can be regulated by a variety of dampers and controls.
Air Filtration
The Ultra-Aire XT includes air filtration to improve indoor air quality.
A MERV-11 media filter is standard. An optional external
filter box with a MERV-14 deep pleated 95% media filter is
available for optimum air filtration and to reduce potentially
harmful airborne particles.
4201 Lien Rd Madison, WI 53704
TOLL-FREE 1-800-533-7533
XT205H
PATENTS:
D570,988
8,069,681
www.thermastor.com
sales@thermastor.com
© 2007 Therma-Stor LLC • Manual P/N TS-693, 01/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra Aire XT105H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Therma-Stor Ultra Aire XT105H

  • Page 1 P/N 4032240 (XT105H) P/N 4031070 (XT155H) P/N 4031560 (XT205H) • Serial No.________________________ Install Date:___________ Sold by: 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com sales@thermastor.com • • • © 2007 Therma-Stor LLC • Manual P/N TS-693, 01/12...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Table of Contents Safety Precautions ................. 3 1. Intended Application ..............4 2. Specifications ................4 3. Installation ................5 3.1 Location ................5 3.2 Electrical Requirements ............5 3.3 Condensate Removal ............6 3.4 Ducting ................6 3.4A Installing Duct Collars ..........
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS Safety Precautions Read the installation, operation and maintenance instructions carefully before installing and operating these devices. Proper adherence to these instructions is essential to obtain maximum benefit from your Ultra-Aire XT indoor air quality systems. READ AND SAVE THESE INSTRUCTIONS •...
  • Page 4: Intended Application

    FOR HVAC INSTALLER ONLY 1. Intended Application for Ultra-Aire XT Models For the ideal installation, draw air from the central part of the home and return it to isolated areas of the home like the bedrooms, den, utility room, or family room. The ductwork of the existing heating system can be used to supply air to the home.
  • Page 5: Installation

    FOR HVAC INSTALLER ONLY 3. Installation If fresh air ventilation is desired, thought should be given to the location for the fresh air ducting. A 6" round insulated duct will 3.1 Location have to be installed on the Ultra-Aire XT and run to the outside of The Ultra-Aire XT can be installed in a variety of locations to meet the structure to bring in fresh air.
  • Page 6: Condensate Removal

    FOR HVAC INSTALLER ONLY 3.3 Condensate Water Removal the collar. A 6" round collar is provided with the unit to attach to the 6" hole in the filter enclosure. The 6" collar should be capped if Condensate drains by gravity via the drain port. Use 3/4" male NPT fresh make-up air is not desired.
  • Page 7: D Installation In A Basement

    FOR HVAC INSTALLER ONLY In cold climates or areas where the outdoor dew point is low the air supply of the existing HVAC system. A backdraft damper is at times, ventilation can be used to dehumidify the structure. required in the duct between the 10" tee and the central supply duct This is accomplished by bringing the dry, low dew point air into to prevent air from being discharged into the basement during central the structure during these times.
  • Page 8: F Installation With (2) Hvac Systems

    A remote control must be used with the systems. Install a separate return for the Ultra-Aire XT as directed Ultra-Aire. Therma-Stor offers the DEH 3000 proprietary controller. above. Discharge air from the dehumidifier should be split and The DEH 3000 allows homeowners the ability to monitor and routed to each supply ducting system.
  • Page 9 ATTENTION INSTALLER WARNING: Allowing yellow wire to contact red or white wire will destroy the transformer. Dehumidifier on : Connect yellow and blue wires. Fan only on : Connect yellow and green (or brown) wires. Accessory power : 24volt AC power supply available for HVAC accessories between yellow and white(and/or red) wire.
  • Page 10: Deh 3000/Deh 3000R Digital Control

    Auto Reboot Operating Voltage: 24 VAC Remote Sensor (DEH 3000R Only) Max Current DMP, COMP, FAN: 1 AMP each To order call Therma-Stor ± Humidity Range/Accuracy: 10 – 95% RH, at 1-800-533-7533 or Humidity Setpoint 35% min – 70% max...
  • Page 11: Maintenance

    FOR HVAC INSTALLER ONLY Figure 15: Refrigeration System of Ultra-Aire XT Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 12: Refrigerant Charging

    FOR HVAC INSTALLER ONLY Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 13: A Checking Compressor Motor Circuits

    FOR HVAC INSTALLER ONLY Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 14: C Replacing Compressor-Nonburn Out

    FOR HVAC INSTALLER ONLY Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 15: Electrical Schematic

    FOR HVAC INSTALLER ONLY Electric Schematics of the Ultra-Aire XT UNIT E-BOX BLK 1 BLU 2 MAKE SURE WIRE IS GRN 9 CAPPED IF DAMPER 1413 N.O. IS NOT USED RED 6 WHT 6 GRN 5 GRN 5 WHT 4 WHT 4 WHT 4 RED 1...
  • Page 16: Service Parts List

    SERVICE PARTS LIST: Ultra-Aire XT Item Part No Description Item Part No Description 4021475 Air Filter 16x20x2" MERV-11 4032196 (XT105) Impeller 4026221 Foot, Leveling, 5/16-18 4026657 (XT155) Impeller 4031085 Condenser Coil 4031089 (XT205) Impeller 4031086 (XT105 & XT155) Evaporator Coil 4031917 (XT105) Compressor Capacitor, 4031575...
  • Page 17: Optional Parts List

    OPTIONAL PARTS LIST: Ultra-Aire XT PART NO. QTY. DESCRIPTION 4024375 Check Damper, 10" Diameter 4028614 Condensate Pump Kit, External 4023672 Duct Damper, 6" Diameter, Electrically Actuated 4025560 Switch, Black, SPDT, On/Off 4024369 Merv 11 Standard Filter 20" x 16 "x 2" 4032221 Filter Box (Needed when MERV 14 filter is used) 4028539...
  • Page 18: Door And Collar Assembly

    DOOR AND COLLAR ASSEMBLY Door Install Insert tab on the bottom of the door, in between the foam installation and the metal side. Push down on the plastic door latch and swing door shut. Once the door is shut release the door latch. Collar Install Remove the 2 round ducts, oval duct seal and small bag of mounting hardware from inside the...
  • Page 19: Warranty

    Miscellaneous. If any term or condition of this Limited Warranty of nature or other causes not arising out of defects in Therma-Stor’s workmanship or material. If a Product or Component is replaced...

This manual is also suitable for:

Ultra aire xt155hUltra aire xt205h

Table of Contents