Download Print this page
Weiser SmartCode 10 Installation And User Manual

Weiser SmartCode 10 Installation And User Manual

Touchscreen electronic deadbolt

Advertisement

66080 001 Rev 01
GED2150
Z Wave® Plus
Installation and User Guide
Required tools
Ruler
Phillips head screwdriver
Additional Tools (depending on application)
Hammer
Wood block
1
Prepare the door and check dimensions
If drilling a new door, use the supplied template and the complete
door drilling instructions available at www.weiserlock.com/doorprep.
Measure to con irm that the hole in
A
the door is either 54 mm (2 1/8 in) or
38 mm (1 1/2 in).
54 mm
2 1/8 in
or
38 mm
1 1/2 in
Note: Additional door preparation may be
required for doors with 38 mm (1 1/2 in) holes.
Consult the deadbolt drilling instructions at
www.weiserlock.com/doorprep.
2
Install the latch and strike
A
Is the door edge chiselled?
YES
or
chiselled
Use latch "A." If the
Use latch "B." If the
latch bolt is not already
latch bolt is not already
extended, extend the
extended, extend the
latch bolt as shown.
latch bolt as shown.
A
Weiser
Technical Support
1 800 501 9471
www.weiserlock.com
Measure to con irm that the backset is
B
either 60 or 70 mm (2 3/8 or 2 3/4 in).
b a
60 or 70 mm
c k
s e
t
2 3/8 or 2 3/4 in
B
Hold the latch in front of the door hole, with the latch
face lush against the door edge.
NO
not
chiselled
A
B
C
Is the D-shaped hole centred in the door hole?
YES
D-shaped hole
No adjustment is required.
Proceed to next step.
1 / 4
Parts in the box
Latch
Interior Assembly
Traditional
Contemporary
A
M
M
B
K
Strike
Keys
C
E
Batteries
Adapter
Mounting
SmartKey
Ring
Plate
Tool
D
G
C
Measure to con irm that the hole in
the door edge is 25 mm (1 in).
25 mm
1 in
actual
size
N
P
D
Which latch are you installing?
B
NO
or
D-shaped hole
Rotate latch face as
shown to extend latch.
E
Install strike on the door frame.
A
Make sure the hole in the door frame is drilled a
minimum of 25 mm (1 in) deep.
B
Exterior Touchscreen
Traditional
Contemporary
F
F
Fasteners
L
SL03031011
03809
R
Q
N
P
S
J
48654
49191
64109
T
U
V
H
Measure to con irm that the door is
D
between 35 mm and 51 mm (1 3/8
and 2 in) thick.
35 – 51 mm
1 3/8 – 2 in
Q
R
S
Latch "A"
Latch "B"
or
B
A
N or P
(2x)
wood
block
Longer screws
install closest to
the door jamb.
S (2x)
C
Q or R (2x)
door frame

Advertisement

loading
Need help?

Need help?

Do you have a question about the SmartCode 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Weiser SmartCode 10

  • Page 1 Exterior Touchscreen Traditional Contemporary Traditional Contemporary Installation and User Guide Fasteners SL03031011 03809 Strike Keys Required tools Batteries Weiser Technical Support Ruler Phillips head screwdriver Adapter Mounting SmartKey 48654 49191 64109 1 800 501 9471 Additional Tools (depending on application) Ring...
  • Page 2 actual Install the exterior touchscreen size What is the diameter of the hole in the door? Install exterior touchscreen and mounting plate. Diameter is 54 mm Diameter is 38 mm Support exterior assembly during (2 1/8 in) (1 1/2 in) mounting plate installation.
  • Page 3 “A” on the lock one time. Perform steps 6A 6C again. If still unsuccessful, consult the Programming and Troubleshooting Guide on the SmartCode 10 Please allow time for the controller to add the lock. Touchscreen page of online at www.weiserlock.com.
  • Page 4 Z Wave device. And, regardless of the performance grades to suit the application. In order to enhance security and reduce vendor, always powered nodes may act as a repeater for Kwikset/Weiser/Baldwin products. risk, you should consult a quali ied locksmith or other security professional.
  • Page 5: Association Groups

    1. Association Groups The lock supports 2 association groups. Per Z-Wave Plus requirements, group 1 is assigned to the Lifeline group. The Lifeline group supports the following unsolicited messages: Battery Report Door Lock Operation Report Notification Report Device Reset Locally Notification Group 2 is available for all Notification Reports and can be used to send notifications to at most 5 other nodes.
  • Page 6 The door lock will only retain valid user code types (0x01, 0x03, and 0x04). All other values will be ignored. If a user code does not exist for the corresponding configuration parameter, the lock will report a value of 0xFF. Any attempts to change the user code for a non-existent user will be ignored.
  • Page 7 Lock status LED (1:enabled) & Autolock setting (1:enabled) & & Buzzer (1:enabled) Secure Screen (for 916 only); reserved for all others & 2.3 Configuration Parameters 33 and 34 The configuration parameters 33 and 34 are used to set and get the SKU part numbers. The SKU is made up of 8 bytes.
  • Page 8: Reset Procedures

    3. Inclusion Procedures Power the lock by placing the battery pack into the lock On the controller, select the option to add a device. On the lock, press button ‘A’. The red LED will illuminate until the add request has been processed. 4.