Di Diagnosis Operation - Delta ASD-B2-0121-B User Manual

Asda-b2 series standard type ac servo drive for network communication application
Hide thumbs Also See for ASD-B2-0121-B:
Table of Contents

Advertisement

Chapter 4 Display and Operation

4.4.4 DI Diagnosis Operation

Following the setting method in Figure 4.6 can perform DI diagnosis operation (parameter
P4-07, Input Status). According to the ON and OFF status of the digital inputs DI1 to DI9,
the corresponding status will display on the servo drive LED display. When the Bit is set to
"1", it means that the corresponding digital input signal is ON. (Please also refer to Figure
4.6)
For example:
Suppose that the servo drive LED display is "1E1".
"E" is hexadecimal, which is equal to "1110" in binary system, and it means that the
digital inputs DI6 ~ DI8 are ON.
Figure 4.6
4-10
(Hexadecimal Display)
Revision June 2010

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASD-B2-0121-B and is the answer not in the manual?

Questions and answers

Oluseye Olumide
February 24, 2025

How can l run the command input correctly

1 comments:
Mr. Anderson
February 24, 2025

To run the command input correctly for the Delta ASDA-B2-0121-B servo drive, follow these steps:

1. Ensure Proper Wiring: Do not change wiring while the power is connected. Verify all connections are secure.

2. Enable Emergency Stop: Ensure the emergency stop function is available before powering on.

3. Set Parameter P3-06: This determines how digital inputs (DI) accept commands, either through an external terminal or communication, as determined by P4-07.

4. Configure Digital Inputs: Set parameters P2-11 (DI2), P2-12 (DI3), and P2-13 (DI4) as needed for functional planning.

5. Check for Faults: If an error occurs (e.g., E0001), check the ROM data and contact Delta support if necessary.

6. Review Encoder and Output Pulse Settings: Ensure P1-76 and P1-46 are correctly set to avoid abnormal signal output.

7. Verify Serial Communication: Ensure proper settings to avoid communication errors.

Following these steps will help ensure the correct operation of the command input.