58.3.2 System configuration for connecting to SIMATIC S7-200/300/400/1200
series (Ethernet connection type: OP communication)
SIMATIC
Ethernet
S7-200/300
Module
/400/1200
series
PLC
*3
Series
Ethernet Module
SIMATIC
CP 243-1
S7-200
CP 243-1 IT
CP 343-1
CP 343-1 Lean
CP 343-1
Advanced-IT
ACCON-NetLink-
PRO compact
SIMATIC
S7-300
- (Built into GOT)
• 10BASE-T
• 100BASE-TX
CP 443-1
CP 443-1
Advanced-IT
ACCON-NetLink-
PRO compact
SIMATIC
S7-400
- (Built into GOT)
SIMATIC
- (Built into GOT)
S7-1200
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
The use of shielded twisted pair cable (STP) is recommended in environments in which the performance against noise is
required.
Connector
conversion
box
Connection cable
Connector
*1
Connection cable
conversion
Cable model
CNB-42S
CNB-37S
CNB-42S
CNB-37S
CNB-42S
Shielded twisted pair cable (STP)
CNB-37S
or unshielded twisted pair cable
(UTP): Category 3, 4, and 5
Shielded twisted pair cable
CNB-42S
(STP): Category 5 and 5e
CNB-37S
CNB-42S
CNB-37S
CNB-42S
CNB-37S
External cable
External cable
box
GT16H-C30-42P(3m)
GT16H-
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
GT16H-C30-42P(3m)
GT16H-
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
GT16H-C30-42P(3m)
GT16H-
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
GT16H-C30-42P(3m)
GT16H-
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
GT16H-C30-42P(3m)
GT16H-
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
GT16H-C30-42P(3m)
GT16H-
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
58. CONNECTION TO SIEMENS PLC
58.3 Ethernet Connection
Communication driver
Ethernet(
), Gateway
SIEMENS OP
GOT
Maximum
GOT
Number of connectable
segment
Model
equipment
length
When PLC: GOT is N:1
The following shows
the number of PLCs for
1 GOT
128 or less
*2
100m
When PLC: GOT is 1:N
The following shows
the number of GOTs for
1 PLC 32 or less
(recommended to 16 or
less)
52
53
54
55
56
57
*4
58
59
58 - 7

Advertisement