Control Inputs And Outputs; Vcb Frequency Inverter Series - BONFIGLIOLI ACTIVE Applications Manual

Hide thumbs Also See for ACTIVE:
Table of Contents

Advertisement

2.2
The modular structure of the frequency inverters enables a wide range of applications
on the basis of the available hardware and software functionality. The functionality of
the control inputs and outputs described in the brief manual and the operating instruc-
tions are extended in the configurations 160, 460 and 260.
2.2.1
The following illustration shows a possible solution of connecting the control terminals
of the VCB frequency inverter in hoist and lift application.
Note:
06/05
06/05

Control inputs and outputs

VCB frequency inverter series

reference speed
FUF
lifting - STR
lowering - STL
positioning - DSS1
DSS2
frequency limitation - FFS1
frequency limitation - FFS2
RESET
frequency contact
operating message
fault message
holding brake
The connection diagram describes the standard configuration of the con-
trol terminals. According to the requirements in the application deviating
connection possibilities are to be configured by the freely programmable
combinations.
In the above connection diagram the holding brake is connected for ex-
ample with the strip X460 of the extension module EAL-1.
{
-
+
mA
-
+
-
+
{
{
X211
1
+10V / 10mA
2
GND 10V
3
+
} S1INA (U)
4
5
+
} S2INA (U)
6
} S3INA (I)
7
+
8
S1OUTA (I)
X210
1
+24V / 150mA
2
GND 24V
3
S1IND
4
S2IND
5
S3IND
6
S4IND
7
S5IND
8
S6IND
9
S7IND
10
S8IND
11
+24V ext.
12
S1OUT
13
S2OUT
14
GND 8V ext.
15
+8V ext.
X209
1
2
S3OUT
3
X460
1
2
S6OUT
3
7
7