Do you have a question about the 9020 and is the answer not in the manual?
Questions and answers
Mizanur Rahman
March 8, 2025
How To Solve 9020 High Voltage Insulation failure Problem.
2 comments:
Mr. Anderson
March 8, 2025
To solve the high voltage insulation failure problem for the Markem-Imaje 9020, follow these steps:
1. Clean the Deflection Plates – Use soapy water to clean the deflection plates and let them dry completely. 2. Check Inside the Print Head – Open the rear cover and clean any ink or moisture buildup. 3. Dry the Area – Ensure all cleaned components are fully dry before reassembling. 4. Inspect for Leaks – Identify and eliminate any sources of current leaks. 5. Check the EHT Block and Print Module – If the issue persists, inspect these components for faults.
These steps should help resolve the insulation failure and restore proper operation.
This answer is automatically generated
Mizanur Rahman
March 9, 2025
@Mr. Anderson Thanks for your Help
cos
March 30, 2025
how i change the date and hours , Sommer houer
Mark Randall
March 5, 2025
81 Default. Drop detection jet 1 (left)
Clean and dry carefully head and cover...
Done this numerous times but error returns
1 comments:
Mr. Anderson
March 5, 2025
To resolve the "81 Default. Drop detection jet 1 (left)" error on a Markem Imaje 9020 after cleaning the head and cover, follow these steps:
1. Check Ink Quality – Ensure that the ink is of the correct viscosity. If it is too thin or too thick, it may affect drop detection. 2. Inspect Print Module Connections – Look for any cut wires in the umbilical that may be causing a connection issue. 3. Verify Jet Detection – Ensure the recovery detector is correctly identifying the jet in the gutter. Clean the nozzle and modulation assembly if necessary. 4. Check Gutter Blockage – Make sure the gutter is not obstructed, and the negative pressure is within the correct range. 5. Adjust Break-Off Point – Use a magnifier to check the drop formation under the break-off point and adjust the potentiometer carefully if needed. 6. Perform Auto-Calibration – Run the auto-calibration function to fine-tune jet stability. 7. Close the Head Cover – Ensure the head cover is properly closed, as safety mechanisms may prevent operation if it's open.
After completing these steps, perform a test print to confirm the issue is resolved.
Need help?
Do you have a question about the 9020 and is the answer not in the manual?
Questions and answers
How To Solve 9020 High Voltage Insulation failure Problem.
To solve the high voltage insulation failure problem for the Markem-Imaje 9020, follow these steps:
1. Clean the Deflection Plates – Use soapy water to clean the deflection plates and let them dry completely.
2. Check Inside the Print Head – Open the rear cover and clean any ink or moisture buildup.
3. Dry the Area – Ensure all cleaned components are fully dry before reassembling.
4. Inspect for Leaks – Identify and eliminate any sources of current leaks.
5. Check the EHT Block and Print Module – If the issue persists, inspect these components for faults.
These steps should help resolve the insulation failure and restore proper operation.
This answer is automatically generated
@Mr. Anderson Thanks for your Help
how i change the date and hours , Sommer houer
81 Default. Drop detection jet 1 (left) Clean and dry carefully head and cover... Done this numerous times but error returns
To resolve the "81 Default. Drop detection jet 1 (left)" error on a Markem Imaje 9020 after cleaning the head and cover, follow these steps:
1. Check Ink Quality – Ensure that the ink is of the correct viscosity. If it is too thin or too thick, it may affect drop detection.
2. Inspect Print Module Connections – Look for any cut wires in the umbilical that may be causing a connection issue.
3. Verify Jet Detection – Ensure the recovery detector is correctly identifying the jet in the gutter. Clean the nozzle and modulation assembly if necessary.
4. Check Gutter Blockage – Make sure the gutter is not obstructed, and the negative pressure is within the correct range.
5. Adjust Break-Off Point – Use a magnifier to check the drop formation under the break-off point and adjust the potentiometer carefully if needed.
6. Perform Auto-Calibration – Run the auto-calibration function to fine-tune jet stability.
7. Close the Head Cover – Ensure the head cover is properly closed, as safety mechanisms may prevent operation if it's open.
After completing these steps, perform a test print to confirm the issue is resolved.