8.
Non Contact Voltage (NCV): > 25V AC
PRESS
PRESS
and
and
HOLD
HOLD
SyMBOLS USED ON LCD
~
AC Measurement
DC Measurement
-
AT
Negative DC Value
Auto Range Active
O.L.
Apo
Overload: Range Exceeded
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
MAX
Minimum Reading
Maximum Reading
%
Duty Cycle Mode
Frequency Mode
V
A
Voltage Measurement
Current in Amps
Ω
Resistance in Ohms
Diode Test
F
Capacitance in Farads
Continuity Test
n
µ
Nano 10
Micro 10
-9
-6
m
k
Milli 10
Kilo 10
-3
3
M
Mega 10
6
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
400mV ˜ 400V
0.1mV ˜ 0.1V
± (0.5% + 4 digits)
1000V
1V
± (0.8% + 10 digits)
Overload Protection:
1000V
AC Voltage Measurement
Range
Resolution
Accuracy
400mV ˜ 750V
0.1mV ˜ 1V
± (2.0% + 5 digits)
Overload Protection:
750V RMS
40 to 400 Hz
Frequency Response:
Minimum Voltage for Frequency Measurement:
200mV
Response:
Averaging
DC Current Measurement
Range
Resolution
Accuracy
400µA
0.1µA
± (1.2% + 3 digits)
2000µA
1µA
Overload Protection:
600V RMS
Voltage:
Current:
2000µA
AC Current Measurement
Range
Resolution
Accuracy
400µA
0.1µA
± (2.0% + 5 digits)
2000µA
1µA
± (1.5% + 5 digits)
40A
0.01A
± (2.9% + 15 digits)
400A
0.1A
± (1.9% + 8 digits)
Overload Protection:
Voltage:
600V RMS
Current:
2000µA
45 to 400Hz
Frequency:
Minimum Current for Frequency Measurement:
400µA or 20A
Averaging
Response:
Resistance Measurement
Range
Resolution
Accuracy
400 Ω ˜ 4M Ω
0.1 Ω ˜ 0.001M Ω
± (1.0% + 4 digits)
40M Ω
0.01M Ω
± (2.0% + 4 digits)
Overload Protection:
600V RMS
Capacitance Measurement
Range
Resolution
Accuracy
40nF ˜ 4000µF
0.01nF ˜ 1µF
± (3.5% + 6 digits)
Overload Protection:
600V RMS
Frequency Measurement
Range
Resolution
Accuracy
9.999Hz ˜ 999.9kHz
0.001Hz ˜ 0.1kHz
± (0.1% + 4 digits)
600V RMS
Overload Protection:
Duty Cycle Measurement
Range
Resolution
Accuracy
0.1 ˜ 99.9%
0.1%
± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection:
600V RMS
Diode Test
Overload Protection Range
Test Current
Open Circuit Voltage
2.0V
Appx. 0.25mA
< 1.6V DC
600V RMS
Continuity Test
Overload Protection
Open Circuit Voltage
600V RMS
< 0.44V
Non Contact Voltage Detector
On Voltage
Appx. 25V AC
WARRANTy
This product is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. During this warranty period,
Klein Tools has the option to repair or replace or refund the purchase price of
any unit which fails to conform to this warranty under normal use and service.
This warranty does not cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse, abuse, neglect, or improper
maintenance. Batteries and damage resulting from failed batteries are not
covered by warranty. A purchase receipt or other proof of original purchase date
will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. Klein Tools shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state. If your Klein product requires
repair or for information on how to exercise your rights under the terms of this
warranty, please contact Klein Tools at 1-877-775-5346.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECyCLE
Caution:
This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
Instruction
Manual
CL1000
ENGLISH
• DATA HOLD
• BACKLIGHT
• WORKLIGHT
• BAR GRAPH
CL1000
• MAX / MIN
• 3-3/4 DIGIT
3999 COUNT LCD
• AUTO / MANUAL
RANGE
• NON CONTACT
VOLTAGE TESTER
0
10
20
www.kleintools.com
139537T
30
40

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CL1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Klein Tools CL1000

  • Page 1 Minimum Current for Frequency Measurement: 400µA or 20A • BACKLIGHT warranty. Klein Tools shall not be liable for loss of use of the instrument or other Averaging Negative DC Value Auto Range Active...
  • Page 2: Function Instructions

    • The bar graph responds much faster than the digital display. The Klein Tools CL1000 is an auto-ranging clamp meter. It measures • The scale of the bar graph is zero to the maximum reading of AC / DC voltage, AC / DC current, resistance, capacitance, frequency, and Duty the selected range.
  • Page 3: Eliminación / Reciclaje

    Valor de CC negativo Autoapagado activo implícitas de comerciabilidad e idoneidad para un propósito específico, están • LUZ DE FONDO limitadas a la garantía expresa. Klein Tools no será responsable por la pérdida de Medición de resistencia Sobrecarga: Determinación automática O.L.
  • Page 4 • Sujete el instrumento a metal para permitir su uso con las manos libres. El CL1000 de Klein Tools es un multímetro de pinza con determinación automática del intervalo. Mide tensión de CA / CC, corriente CA / CC, Gráfico de barras Duty resistencia, capacitancia, frecuencia y ciclo de servicio.
  • Page 5: Garantie

    Réponse : de qualité marchande et d’adéquation à un but particulier, sont limitées à la • GRAPHIQuE Fonction de Mise hors garantie expresse. Klein Tools n’assumera aucune responsabilité au titre de la Mesure de la résistance Surcharge : O.L. À bARRES tension automatiquement perte d’utilisation de l’instrument ou pour d’autres dommages, frais ou pertes...
  • Page 6: Spécifications Générales

    • Attachez l’instrument à une surface en métal afin d’avoir les mains libres. L’appareil Klein Tools CL1000 est un multimètre à sélection automatique Graphique à barres de gamme. Il mesure la tension c.a. / c.c., le courant électrique c.a., la •...

Table of Contents