6. Use a 9/16" socket to remove the two ramp-yoke fasteners and remove the yoke from
the ramp. Take Note that the ramp will fall when the fasteners are removed. Make sure
the ramp is supported before removing the fasteners. Retain fastener hardware for
installation.
7. Remove the hitch pin from the Lift Motor clevis pin fastener. Slide the clevis pin to the
right enough for the pin to clear the left side of the mounting bracket. Then lift and
remove the Lift Motor Assembly from the mounting bracket. The clevis pin does not
need to be removed to remove the Lift Motor Assembly. Retain fastener hardware for
installation.