You can find them listed in chapter "Product description". Instructions manuals for accessories and replacement parts Tip: To ensure reliable setup and operation of your VEGASWING 63, we offer accessories and replacement parts. The corresponding doc- umentations are: 30173 - Electronics module VEGASWING series 60 34296 - Protective cover 29750 - Lock fitting for VEGASWING 63 unpressurized...
This symbol indicates special instructions for Ex applications. List The dot set in front indicates a list with no implied sequence. à Action This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. VEGASWING 63 • - Relay (DPDT)
During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use The VEGASWING 63 is a sensor for level detection. You can find detailed information on the application range in chapter "Product description".
2.6 CE conformity This device fulfills the legal requirements of the applicable EC guidelines. By attaching the CE mark, VEGA provides a confirmation of successful testing. You can find the CE conformity declaration in the download area of www.vega.com.
IEC 61511" (optional) Supplementary instructions manual "Plug connector for level sensors" (optional) Ex-specific "Safety instructions" (with Ex versions) if necessary, further certificates The VEGASWING 63 consists of the following components: Constituent parts Housing cover Housing with electronics Process fitting with tuning fork Fig.
In addition to the type label outside, you can also find the serial number on the inside of the instrument. 3.2 Principle of operation VEGASWING 63 is a point level sensor with tuning fork for level Application area detection.
3 Product description 3.3 Operation The switching condition of VEGASWING 63 with plastic housing can be checked when the housing is closed (signal lamp). With the basic setting, products with a density > 0.7 g/cm³ (0.025 lbs/in³) can be detected. The instrument can be adapted if products with lower density are to be measured.
You can find the specifications in chapter "Technical data" or on the type label. In general, VEGASWING 63 can be installed in any position. The Switching point instrument simply has to be mounted in such a way that the tuning fork is at the height of the desired switching point.
Page 11
Fig. 2: Vertical mounting Switching point approx. 13 mm (0.51 in) Switching point with lower density Switching point with higher density Switching point approx. 27 mm (1.06 in) Fig. 3: Horizontal mounting Switching point VEGASWING 63 • - Relay (DPDT)
Page 12
Rain and condensation water can thus drain off. This applies mainly to outdoor mounting as well as installation in areas where high humidity is expected (e.g. through cleaning processes) or on cooled or heated vessels. VEGASWING 63 • - Relay (DPDT)
Fig. 6: Measures against moisture penetration Transport Caution: Do not hold VEGASWING 63 on the tuning fork. Particularly with flange or tube versions, the tuning fork can be damaged just by the weight of the instrument. Transport coated instruments very carefully and avoid touching the tuning fork.
Page 14
Inflowing medium measurement signals can be generated. For this reason, mount VEGASWING 63 at a position in the vessel where no disturbances, e. g. from filling openings, agitators, etc., can occur. This applies particularly to instrument types with long extension tube.
Page 15
Due to agitators, vibrations or similar, the level switch can be subjected to strong lateral forces. For this reason, do not use an overly long extension tube for VEGASWING 63, but check if you can mount a VEGASWING 61 level switch on the side of the vessel in horizontal position.
Page 16
Fig. 9: Lateral straining of VEGASWING 63 Enamel coating Instruments with enamel coating should be treated very carefully and shocks should be avoided. Unpack VEGASWING 63 directly before installation. Insert VEGASWING 63 carefully into the vessel opening and avoid touching any sharp vessel parts.
Take note of the general installation regulations. As a rule, connect VEGASWING 63 to vessel ground (PA), or in case of plastic vessels, to the next ground potential. On the side of the housing there is a ground terminal between the cable entries.
The following illustrations apply to the non-Ex as well as to the EEx-d version. Housing overview Fig. 10: Material versions, single chamber housing Plastic (not with EEx d) Aluminium Stainless steel (not with EEx d) Filter element for pressure compensation (not with EEx d) VEGASWING 63 • - Relay (DPDT)
Page 19
DIL switch for mode adjustment DIL switch for switching point adaptation Ground terminal Connection terminals We recommend connecting VEGASWING 63 in such a way that the Wiring plan switching circuit is open when there is a level signal, line break or failure (safe condition).
DIL switch for sensitivity adjustment (3) Note: For test purposes, immerse the tuning fork of VEGASWING 63 always in liquids. Do not test the function of VEGASWING 63 with the hand. This can damage the sensor. 6.2 Adjustment elements Fig. 13: Oscillator SWE60R - Relay output...
Level Switching status Control lamp Mode A Overflow protection (6) (7) Relay energized Green Mode A Overflow protection (6) (7) Relay deenergized Mode B Dry run protection (6) (7) Relay energized Green VEGASWING 63 • - Relay (DPDT)
Page 22
6 Set up Level Switching status Control lamp Mode B Dry run protection (6) (7) Relay deenergized Failure of the supply voltage (mode A/B) (6) (7) Relay deenergized off Failure (6) (7) Relay deenergized flashes red VEGASWING 63 • - Relay (DPDT)
24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is available to you 7 days a week round-the-clock. Since we offer this service world-wide, the support is only available in the English language.
In general, all electronics modules of series SW60 can be inter- changed. If you want to use an electronics module with a different signal output, you carry out the complete setup. You find the necessary, suitable operating instruction on our homepage. VEGASWING 63 • - Relay (DPDT)
If a repair is necessary, please proceed as follows: You can download a return form (23 KB) from our Internet homepage www.vega.com under: "Downloads - Forms and certificates - Repair form". By doing this you help us carry out the repair quickly and without having to call back for needed information.
Correct disposal avoids negative effects to persons and environment and ensures recycling of useful raw materials. Materials: see chapter "Technical data" If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. VEGASWING 63 • - Relay (DPDT)
Page 28
The contact is then no longer suitable for switching low-level signal circuits. Contact material (relay contacts) AgNi or AgSnO and Au plated Modes (adjustable) Max. detection or overflow/overfill protection VEGASWING 63 • - Relay (DPDT)
Page 29
(392 °F) Fig. 27: Influence of the process temperature on the switching point Shifting of the switching point in mm (in) Process temperature in °C (°F) Switching point at reference conditions (notch) Tuning fork VEGASWING 63 • - Relay (DPDT)
Page 30
(739,7) (928,2) Fig. 29: Influence of the process pressure to the switching point Shifting of the switching point in mm (in) Process pressure in bar (psig) Switching point at reference conditions (notch) Tuning fork VEGASWING 63 • - Relay (DPDT)
Page 31
-50 … +200 °C (-58 … +392 °F) VEGASWING 63 with ECTFE coating -50 … +150 °C (-58 … +302 °F) VEGASWING 63 with PFA coating -50 … +150 °C (-58 … +302 °F) VEGASWING 63 • - Relay (DPDT)
Page 32
Process temperature in °C (°F) (928) (580) (290) -1 (-14,5) 0 °C -50 °C 50 °C 100 °C 150 °C 200 °C 250 °C (32 °F) (-58 °F) (122 °F) (212 °F) (302 °F) (392 °F) (482 °F) VEGASWING 63 • - Relay (DPDT)
Page 33
1 … 8 VA (AC), approximately 1.5 W (DC) Power consumption Electrical protective measures IP 66/IP 67 Protection rating Overvoltage category Protection class Approvals Depending on the version, instruments with approvals can have different technical data. VEGASWING 63 • - Relay (DPDT)
Page 34
9 Supplement For these instruments, the corresponding approval documents have to be taken into account. These are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and "serial number search" as well as via "Downloads" and "Approvals".
Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellectuelle. Pour plus d'informations, on pourra se référer au site http://www.vega. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad industrial. Para mayor información revise la pagina web http://www.vega.com Линии...