    Installation, use and maintenance guide SlimQuadro Idra 14 INDEX 1 - INTRODUCTION ..........................7 1.1 GENERAL GUIDELINES ..........................7 1.2 SAFETY GUIDELINES ............................. 7 1.2.2 GENERAL WARNINGS ................................8 1.3 TRANSPORTATION AND STORAGE ......................8 2 – TECHNICAL CHARACTERISTICS* ....................9 3 –...
  • Page 3 Installation, use and maintenance guide SlimQuadro Idra 14 7 ADDITIONAL ROOM TEMPERATURE THERMOSTAT / ADDITIONAL CHRONOTHERMOSTAT (not supplied) ..............................38 7.1 OPERATING WITH THE ADDITIONAL ROOM TEMPERATURE THERMOSTAT (NOT SUPPLIED ) ..38 7.2 OPERATING WITH THE ADDITIONAL CHRONOTHERMOSTAT (NOT SUPPLIED) ........38 8 CLEANING AND MAINTENANCE ......................
  • Page 4 Installation, use and maintenance guide SlimQuadro Idra 14 DICHIARAZIONE DI CONFORMITA' DECLARATION OF CONFORMITY La THERMOROSSI S.P.A., VIA GRUMOLO N° 4 36011 ARSIERO (VI), sotto la sua esclusiva responsabilità DICHIARA che l’apparecchiatura descritta in appresso: DECLARES that the product: Descrizione...
  • Page 5 SLIMQUADRO IDRA 14, apparecchio per il riscaldamento domestico, con acqua, alimentato a pellet di legno SLIMQUADRO IDRA 14, residential space heating appliance with water fired by wood pellets EN 14785:2006 Numero di tipo, lotto , serie o qualsiasi altro elemento che consenta l'identificazione del prodotto da...
  • Page 6 Installation, use and maintenance guide SlimQuadro Idra 14 Prestazione dichiarata / Declared performance Specifica tecnica armonizzata: EN 14785:2006 Harmonized technical specification: Caratteristiche Essenziali Prestazione / Performance Essential characteristics Sicurezza antincendio / Fire safety Reazione al fuoco / Reaction to fire...
  • Page 7: Introduction

    If the appliance is sold or transferred to another user ensure that the manual is handed over with it. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
  • Page 8: General Warnings

    Installation, use and maintenance guide SlimQuadro Idra 14 1.2.2 GENERAL WARNINGS Attention: the appliance must be connected to a system provided with a PE conductor (in compliance with the specifications of 2006/95/EC, concerning low voltage equipment).Before installing the appliance check the efficiency of the earth circuit of the power supply system.
  • Page 9: Technical Characteristics

    Installation, use and maintenance guide SlimQuadro Idra 14 2 – TECHNICAL CHARACTERISTICS* SLIMQUADRO IDRA 14 Height (mm) Depth (mm) Width (mm) 1109 Empty weight of the appliance (Kg) Firebox power Min. / Max. (KW) 4.89 / 14.29 Rated power Min. / Max. (KW) 4.67 / 13.33...
  • Page 10 Installation, use and maintenance guide SlimQuadro Idra 14 1109 VALVOLA SICUREZZA 1/2" F RITORNO 3/4" F MANDATA 3/4" F CARICO SCARICO 3/4" M Legenda FUMI SMOKE VALVOLA SICUREZZA 1/2'’ F. SAFETY VALVE 1/2'’ F. RITORNO 3/4 ‘’F RETURN 3/4 ‘’F MANDATA 3/4 ‘’F...
  • Page 11: General Description

    Installation, use and maintenance guide SlimQuadro Idra 14 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
  • Page 12: Main Components Of The Appliance

    Installation, use and maintenance guide SlimQuadro Idra 14 3.4 MAIN COMPONENTS OF THE APPLIANCE Pocket for heating system PTC sensor and Burner cleaning motor thermostat bulb 100°C reset System circulating pump Automatic relief valve Smoke suction unit Tube bundle inspection cover...
  • Page 13: Installation

    Installation, use and maintenance guide SlimQuadro Idra 14 4 - INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Above all keep in mind that the flooring of the room in which the stove is being installed must withstand the weight of the stove with the added weight of the pellet load and the water contained in it.
  • Page 14: Gluing The Glass Panes To The Front Panel

    Installation, use and maintenance guide SlimQuadro Idra 14 4.3 GLUING THE GLASS PANES TO THE FRONT PANEL After unpacking the glass panes of the casing, disassemble the front panel as described below. Prior to beginning any operation, lay a soft sheet...
  • Page 15: Handle

    Installation, use and maintenance guide SlimQuadro Idra 14 Legenda 4.5 HANDLE Figura Figure MANIGLIA HANDLE ALLINEAMENTO ALIGNMENT Your appliance is supplied with a handle for opening and closing the firebox door to facilitate cleaning (see paragraph 8). The handle is also designed to be used for regulating the channelling flow rate. When not in use, the handle can be stowed on the side of the appliance if the hook provided is attached to the stove.
  • Page 16 Installation, use and maintenance guide SlimQuadro Idra 14 Figura 7 Vano Viti Staffa DETTAGLIO C DETTAGLIO D Legenda Figura Figure Vano Compartment Viti Screws Staffa Bracket DETTAGLIO DETAIL MANDATA IMPIANTO PLANT DELIVERY USCITA FUMI SMOKE OUTLET RITORNO IMPIANTO PLANT RETURN...
  • Page 17: Hydraulic Connection

    Installation, use and maintenance guide SlimQuadro Idra 14 5 – HYDRAULIC CONNECTION 5.1 HYDRAULIC DIAGRAM 1 System circulating pump 2 Automatic relief valve 3 Sensor PTC appliance’s body 4 Thermostat bulb 100°C reset 6 Closed expansion tank X Heating plant return...
  • Page 18: Guidelines For Plants With Zone Valves

    Installation, use and maintenance guide SlimQuadro Idra 14 5.1.1 GUIDELINES FOR PLANTS WITH ZONE VALVES Note: above 61°C, the generator pump is always active as it is essential to dissipate the heat; therefore the solenoid valve must be open for the following reasons •...
  • Page 19: Hydraulic Diagram With Heating Only

    Installation, use and maintenance guide SlimQuadro Idra 14 5.2 HYDRAULIC DIAGRAM WITH HEATING ONLY s c a r i c o VM3 VT andata impianto riscaldamento ritorno impianto riscaldamento saracinesca VNR : valvola di non ritorno VEC : vaso di espansione chiuso per protezione impianto...
  • Page 20: Example Of Hydraulic Diagram With Interspaced Boiler Coils Or Boiler Coils

    Installation, use and maintenance guide SlimQuadro Idra 14 5.3 EXAMPLE OF HYDRAULIC DIAGRAM WITH INTERSPACED BOILER COILS OR BOILER COILS VM3 VT s c a r i c o andata impianto riscaldamento ritorno impianto riscaldamento saracinesca VNR : valvola di non ritorno...
  • Page 21: Example Of Hydraulic Diagram With Boiler Coils And Heating System

    Installation, use and maintenance guide SlimQuadro Idra 14 5.4 EXAMPLE OF HYDRAULIC DIAGRAM WITH BOILER COILS AND HEATING SYSTEM Co n t a t t o Cr o n o t e r m o s t a t o...
  • Page 22: Hydraulic Diagram With Thermocell (Or Thermopuffer) + Additional Thermopuffer + High Temperature Heating And Low Temperature Heating

    Installation, use and maintenance guide SlimQuadro Idra 14 5.5 HYDRAULIC DIAGRAM WITH THERMOCELL (OR THERMOPUFFER) + ADDITIONAL THERMOPUFFER + HIGH TEMPERATURE HEATING AND LOW TEMPERATURE HEATING. Sonda PT 100 S1 ai pin 1 e 2 della morsettiera CN5 A ttenzione : ch iudere tutti i fori...
  • Page 23: Instructions For Executing The Hydraulic System Closed Expansion Tank

    The nominal volume of the additional closed expansion tank must be sized in relation to the volume of expansion of the water contained in the system. Thermorossi prescribes that the size of the additional closed expansion tank must be equal to 10% of the water contained in the system.
  • Page 24: Use Of The Appliance

    Installation, use and maintenance guide SlimQuadro Idra 14 6 – USE OF THE APPLIANCE The appliance, when operating, could be hot to the touch, particularly the door of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
  • Page 25 Installation, use and maintenance guide SlimQuadro Idra 14 THERMO ACS Enables you to activate control of a boiler (if installed) for domestic hot water assigning absolute priority to the boiler requirements before replenishing the system. This screen only appears if the optional sensor is connected to the appliance (See para. 6.9)
  • Page 26: Description Of The Power Panel

    Installation, use and maintenance guide SlimQuadro Idra 14 6.2 DESCRIPTION OF THE POWER PANEL The components of the power panel are described below: 1) Electrical power outlet 220V-240V 50Hz 2) Main switch 0/I. 3) Test light for pellet feed motor.
  • Page 27 Installation, use and maintenance guide SlimQuadro Idra 14 3) Now press the Scroll Buttons to select the hour at which you wish the appliance to start up automatically (ON1). Once the hour is set confirm the value by pressing the Degrees Button. When scrolling the ON1 values the OFF1 values will scroll as well; this is to avoid setting a shut off time that is earlier than the start up time.
  • Page 28 Installation, use and maintenance guide SlimQuadro Idra 14 Using the same logic we can copy the programmed cycles to the other days. 7) To conclude the programming operations simply press the Menu Button several times to exit the box until the initial screen will appear.
  • Page 29: Level: Operating Level Setting

    Installation, use and maintenance guide SlimQuadro Idra 14 When is it important to use the CHRONO function? In systems configured like the diagram on the right, where the appliance is connected directly to the system, without the use of external chronothermostats. In this case it is necessary to set the hour programs to prevent the appliance from being stressed by uncontrolled ON and OFF cycles.
  • Page 30 Installation, use and maintenance guide SlimQuadro Idra 14 After a few seconds the following screen will appear on the display: Press one of the two Scroll Buttons and the following screen will appear (Select ON to activate). Confirm the selection by pressing the Degrees Button and the following screen will appear: Press the Scroll Buttons to set the activation temperature for Sensor S2.
  • Page 31: Acs Summer: Activation Of The Boiler Tube Control From A Chrono Command

    Installation, use and maintenance guide SlimQuadro Idra 14 By setting THERMOCONTROL ON , when the puffer is requesting heat the temperatures detected by the sensors S1 and S2 and the word PUF will appear on the display. When is it important to use the THERMOCONTROL function? In systems configured like the diagram on the right, where the appliance is connected directly to a stratification puffer.
  • Page 32: T.ambient: Controlling The Room Temperature

    Installation, use and maintenance guide SlimQuadro Idra 14 ATTENTION: If an external chronothermostat is connected to the appliance, it is not necessary to program any operating time band as the appliance will follow the cycles set in the external chronothermostat. Consequently simply press the Menu Button several times to exit the screen, until the initial screen appears.
  • Page 33: Thermo Acs: Controlling A Configured Boiler Tube In A System

    Installation, use and maintenance guide SlimQuadro Idra 14 Press one of the two Scroll Buttons and the following screen will appear (Select ON to activate). Press the Menu Button several times, to confirm and exit the screen, until the initial screen appears. .
  • Page 34 Installation, use and maintenance guide SlimQuadro Idra 14 ATTENTION: If the optional sensor is not connected to the appliance or if it is interrupted, it will not be possible to view and consequently activate the THERMO ACS function. The THERMO ACS function can be activated by proceeding as follows:...
  • Page 35: Operation Of The Generator

    Installation, use and maintenance guide SlimQuadro Idra 14 When is it important to use the THERMO ACS function? In systems configured like the nearby diagram, where the appliance is connected directly to a domestic hot water boiler tube and to the system.
  • Page 36: Setting Range

    Installation, use and maintenance guide SlimQuadro Idra 14 ATTENTION: The STOP mode must be considered an overtemperature pre-allarm, and therefore cannot be considered a normal operating stage. WAIT ON : when the appliance is restarted while hot where the water temperature is higher than 63°C the appliance does not start immediately, but the circulating pump will still be active.
  • Page 37: Manual Operating Cycle

    Installation, use and maintenance guide SlimQuadro Idra 14 6.10.4 MANUAL OPERATING CYCLE The manual cycle is indicated on the display by the power bars. The power expressed in this cycle remains always constant independently from the power absorbed by the system. As always, the system's circulating pump is activated at the anticondensation temperature, that is above 61°C.
  • Page 38: Additional Room Temperature Thermostat / Additional Chronothermostat (Not Supplied)

    230 V or lower voltages as this would seriously damage the control board, and is not covered by warranty. ATTENTION: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the appliance not starting up, smoke leaks, breakage of the lighting component.
  • Page 39 Installation, use and maintenance guide SlimQuadro Idra 14 Legenda Cronotermostato Modem Chronothermostat - Modem Contatti 9-10 della morsettiera CN7 Contacts 9-10 of the terminal block CN7 Termostato Ambiente Room Temperature Thermostat Contatti 7-8 della morsettiera CN7 Contacts 7-8 of the terminal block CN7...
  • Page 40: Cleaning And Maintenance

    Installation, use and maintenance guide SlimQuadro Idra 14 8 CLEANING AND MAINTENANCE Due to the frequent cases we have encountered of the use of poor quality pellets, users are advised that it is mandatory to use, in this appliance, pellets certified in accordance with the regulations in force for the Italy UNI market or for the European EN market.
  • Page 41 Installation, use and maintenance guide SlimQuadro Idra 14 PelletPower Figura 2 Figura 1 Figura 4 Figura 3 Figura 5 Figura 6 Legenda Figura Figure Page 41...
  • Page 42: Smoke Discharge Tube And Ventilation Of The Rooms

    Installation, use and maintenance guide SlimQuadro Idra 14 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 43: Smoke Outlet

    Installation, use and maintenance guide SlimQuadro Idra 14 9.3 SMOKE OUTLET The smoke channel, the exhaust pipe, chimney and flue outlet (defined as the system for the evacuation of combustion products), are parts of the heating system and they must comply with the legislative requirements of the Ministerial Decree DM 37/08 (ex Italian Law 46/90) and to the applicable specific installation regulations, according to the type of fuel.
  • Page 44: Controls Prior To Installing The Appliance

    Installation, use and maintenance guide SlimQuadro Idra 14 COMIGNOLO E CANNA FUMARIA SECONDO NORMA UNI 10683 LASTRA DI COPERTURA LAMIERA DI ACCIAIO INTERNO ESTERNO A TENUTA STAGNA ISPEZIONE ISPEZIONE LEGENDA COMIGNOLO E CANNA FUMARIA SECONDO NORMA UNI 10683 CHIMNEY CAP AND FLUE OUTLET ACCORDING TO UNI 10683...
  • Page 45 Installation, use and maintenance guide SlimQuadro Idra 14 the smoke tube is installed in a fixed position it is advisable to provide inspection openings for clean-out purposes especially in the horizontal sections. See the diagram. These openings are essential to allow for the removal of ash and unburned products which tend to accumulate along the discharge path.
  • Page 46: Alarms

    ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance .
  • Page 47: Electrical Wiring

    Installation, use and maintenance guide SlimQuadro Idra 14 11 - ELECTRICAL WIRING The electronic board is installed in the bottom right part, as indicated in the following figure: Sonda PT 100 (S2) optional { Sonda PT 100 (S1) optional } oppure { Sonda TAMBIENT optional }...
  • Page 48: Information For The Skilled Technician

    Installation, use and maintenance guide SlimQuadro Idra 14 12 - INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR POSITION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 49 Installation, use and maintenance guide SlimQuadro Idra 14 • At the first startup, run the heater at the maximum power in a well-ventilated room, in order to dispose of the smoke generated by the complete dryness and baking of the silicates contained in the enamel coating of the combustion chamber.
  • Page 50: Troubleshooting Cause / Solution

    Installation, use and maintenance guide SlimQuadro Idra 14 12.3 TROUBLESHOOTING CAUSE / SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE “NO PELLET – CLEAN BURNER” ALARM IS SHOWN ON THE DISPLAY...
  • Page 51: Spare Parts (Part 1/3)

    Installation, use and maintenance guide SlimQuadro Idra 14 PROBLEM POSSIBLE CAUSE SOLUTION ROOM TEMPERATURE THERMOSTAT SET TOO LOW, APPLIANCE OPERATES THE APPLIANCE MUST OPERATE FOR MORE HOURS WITH INTERMITTENTLY MORE POWER: SET A HIGHER ROOM TEMPERATURE THE APPLIANCE SHOULD OPERATE FOR MORE TIME AND THE TEMPERATURE OF THE ROOM IS TOO LARGE, THE WALLS ARE COLD.
  • Page 52: Spare Parts

    70018083 70018086 FIANCO SINISTRO 70018088 70018107 70018087 Pannello frontale senza vetri 70018084 FIANCO DESTRO 60013860 Vetro DX basso SX alto bianco 60013861 Vetro DX basso SX alto rosso 60013862 Vetro DX basso SX alto nero 60013863 Vetro SX basso DX alto bianco 60013864 Vetro SX basso DX alto rosso 60013865...
  • Page 53: Spare Parts (Part 2/3)

    70018115 Sportellino completo 70015966 60004921 Coperchio completo 70016445 Pozzetto GUARNIZIONE 70016436 Isolazione 70016443 COMPLETA 70016463 60012583 70015135 MANIGLIA 70016474 70015962 70016473 70019194 Pannello comandi 60012595 60014109 Motoriduttore 70010234 Bussola fissaggio motore 70016453 70011497 Flangia 60011428 Guarnizione 70016344 70010402 Gruppo alimentazione pellet Aspiratore 70018881 60010185 Boccola...
  • Page 54: Spare Parts (Part 3/3)

    60010336 Treccia D.5 70014154F Porta in ghisa 70016459 70014780 Profilo laterale 60013919 Treccia D.8 70015872 Chiusura 70015873 Protezione chiusura 70016195 70016046 Vite 70015112 70015221 Cerniera Vetro 60011215 70015894 Dado ribassato Porta completa 70016476 60013891 70017794 60013635 60014016 70016263 70017798 70017793 60011644 70015952 70018770...
  • Page 55: Keys

    Installation, use and maintenance guide SlimQuadro Idra 14 13.4 KEYS Legenda FIANCO SINISTRO LEFT PANEL Pannello frontale senza vetri Front panel without glass pane Vetro DX basso SX alto bianco Glass RH bottom LH top white Vetro DX basso SX alto rosso...
  • Page 56 Installation, use and maintenance guide SlimQuadro Idra 14 NOTES Page 56...
  • Page 57 Installation, use and maintenance guide SlimQuadro Idra 14 NOTES Page 57...
  • Page 58 Installation, use and maintenance guide SlimQuadro Idra 14 NOTES Page 58...