Test
MIL-STD-810F
MIL-STD 901D
MIL-STD-1275B
MIL-STD-1399
Section 7.3

EMC and Environmental Type Tests

The RUGGEDCOM M969 has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
40
Description
ESD
Enclosure Contact
Radiated RFI
Enclosure ports
Burst (Fast Transient)
DC Power ports
AC Power ports
Earth ground ports
Surge
DC Power ports
Description
CS115
CS116
RS101
RS103
Low Pressure Altitude Method 500.4 Procedure I Storage
Low Pressure Altitude Method 500.4 Procedure II Operational
High Temperature Method 501.4 Procedure I Storage
High Temperature Method 501.4 Procedure II Operational
Low Temperature Method 502.4 Procedure I Storage
Low Temperature Method 502.4 Procedure II Operational
Temperature Shock Method 503.4 Procedure I Storage
Acceleration Method 513.5 Procedure II
Salt Fog Method 509.4 Procedure I
Vibration Method 514.5
High Impact Shock Test
Power Quality
DC Magnetic Field Testing Section 070 Part 1
Enclosure Air
Signal ports
Signal ports
± 4 kV line-to-earth, ± 2 kV line-to-line
± 2 kV line-to-earth, ± 1 kV line-to-line
Installation Guide
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
EMC and Environmental Type Tests
RUGGEDCOM M969
Severity
Levels
4
4
x
x
4
4
4
4
3