Sealey VS912 Instructions page 4

Thermal imaging camera

Advertisement

4.12.
Time Setting
4.12.1.
in the clock menu, you can set the time and date.(fig.7)
4.12.2.
Press "menu2 key to select menu.
4.12.3.
Press "up" or "down" key to scroll through menu, select clock menu by pressing select.
4.12.4.
Press "left" or "right" key to select time parameter to be changed.
4.12.5.
change value by pressing "up" or "down" key.
4.12.6.
After setting, press "menu" key to exit.
Year
month day
Hour
minute
4.13.
image capture and Storage
4.13.1.
the camera can store up to 25,000 images on the micro sd card.
4.13.2.
Press image capturing button screen will display "store photo yes or no" Press "menu" key to save photo, press "select" key to delete
captured image.
4.13.3.
if "no sd" is displayed in lower left corner of screen this means sd card is missing.
4.13.4.
if "full" is displayed at the lower left corner of screen, it indicates that sd card is full.
4.14.
check internal storage
4.14.1.
Press "menu" key to enter menu.
4.14.2.
select image storage by using "up" or "down" key.
4.14.3.
Press "select" Key.
4.14.4.
scroll up or down using the "up" or "down" keys to select required image.
4.14.5.
Press "select" key to view the image.
4.14.6.
Press "up" key and the screen will display "delete photo yes no"
4.14.7.
Press "menu" key to delete image or "select" key to keep image.
4.14.8.
Press "menu" button to exit
5. noTeS
5.1.
All objects radiate infrared energy. The radiated quantity of infrared energy is based on the actual temperature and radiation coefficient
of the surface. the camera can sence the infrared energy on the objects surface and estimate the temperature based on the amount
of energy detected. Many objects (eg. metal, wood, water and skin) can easily radiate energy, it has a high radiation coefficient
(greater than 90%), so it is easy to get an accurate measured value. this method is not suitable to a glossy surface or coated metal as
there radiation coefficient is less than 60%. To accurately measure the low radiation coefficient materials. Calculate the radiation
coefficient and adjust camera accordingly to make readings more accurate.
5.2.
emissivity
5.2.1.
Press "menu" key select emissivity by scrolling up or down and pressing "select" key.
5.2.2.
the default value is 0.95 this can be altered by using the "up" and "down" keys.