Spring-loaded terminals
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
Single chamber housing
-
Connection cable
Configuration
-
Wire cross-section
-
Wire resistance
-
Tensile strength
-
Standard length
-
Max. length
-
Min. bending radius
-
Diameter
-
Colour - standard PE
-
Colour - standard PUR
-
Colour - Ex-version
-
Adjustment elements
DIL switch for measuring range selection
range 1
-
range 2
-
range 3
-
Power supply
Operating voltage
Electrical protective measures
Protection rating
Plastic housing
-
Aluminium and stainless steel standard
-
VEGACAP 62 • - two-wire
l
or:
l
for wire cross-section up to 1.5 mm² (AWG 16)
l
or:
l
four wires, one suspension cable, one breather
capillary, screen braiding, foil, mantle
0.5 mm²
< 0.036 Ω/m (0.011 Ω/ft)
> 1200 N (270 pounds force)
5 m (16.4 ft)
1000 m (3280 ft)
25 mm (with 25 °C/77 °F)
approx. 8 mm
Black
Blue
Blue
0 ... 20 pF
0 ... 85 pF
0 ... 450 pF
10 ... 36 V DC (via the signal conditioning instru-
ment)
IP 66/IP 67
IP 66/IP 68 (0.2 bar)
2)
A suitable cable is the prerequisite for maintaining the protection rating.
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
2)
9 Supplement
31
Need help?
Do you have a question about the VEGACAP 62 and is the answer not in the manual?
Questions and answers