13) Indoor unit fan control for energy saving for cooling
Enable or disables the power-saving function by controlling the indoor unit fan rotation when
the outdoor unit is stopped during cooling operation.
Setting description
Disable
Enable
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the
setting on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low
speed..
( ... Factory setting)
Function number
Setting value
49
- (06 - 87) -
00
01