Cat Rate; Cat Tot - Yaesu FT-891 Advance Manual

Hf/50 mhz transceiver
Hide thumbs Also See for FT-891:
Table of Contents

Advertisement

Menu Mode
05-01 NB WIDTH
Function: Sets the duration of the noise blanking pulse to match various types of noise
compatible with the noise blanker function.
Available Values: 1/3/10 ( msec )
Default: 3msec
Description: Reduces long duration noise as well as pulse noise by changing the setting.
05-02 NB REJECTION
Function: Selects the level of noise attenuation.
Available Values: 10/30/50 ( dB )
Default: 30dB
05-03 NB LEVEL
Function: Sets the noise blanker level.
Available Values: 0 - 10
Default: 5
Description: Sets the noise blanker level to reduce pulse noise such as noise caused
by automotive ignition systems. The higher the setting, the higher the noise
blanker level becomes.
05-04 BEEP LEVEL
Function: Sets the beep level.
Available Values: 0 - 100
Default: 30
Description: Sets the beep sound volume level. The higher the setting, the louder the
sound becomes.
05-05 RF/SQL VR
Function: Select the operation mode of the RF/SQL knob.
Available Values: RF/SQL VR
Default: RF

05-06 CAT RATE

Function: Sets the baud rate for a CAT command input.
Available Values: 4800/9600/19200/38400 ( bps )
Default: 4800bps
Description: Sets the baud rate for a CAT command input.

05-07 CAT TOT

Function: Sets the Time-Out Timer for a CAT command input.
Available Values: 10/100/1000/3000 ( msec )
Default: 10ms
Description: Sets the Time-Out Timer countdown time for a CAT command input.
78
FT-891 Advance Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FT-891 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF