Removing The Compressor Casing - ABB A175-M66 Operation Manual

Hide thumbs Also See for A175-M66:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
8
Disassembly and assembly
8.5

Removing the compressor casing

Removing wall insert
Figure 29: Removing wall insert
1. Loosen screws (72011) and remove with washers (72008).
2. To secure the wall insert, screw in one screw (72011) a third of the way.
3. Press off wall insert with three press-off screws (90900) until the lifting device
(90190/90195) can be fitted.
4. Using shackle (90195) and lifting gear, fit lifting device (90190) to wall insert (77000).
5. Put on shackle (90195) and fasten to lifting gear.
6. Remove locking screw (72011).
7. Pull out wall insert (77000).