Panasonic KX-NCP500 Pc Programming Manual page 291

Pure ip-pbx
Hide thumbs Also See for KX-NCP500:
Table of Contents

Advertisement

Programming Manual References
None
Feature Manual References
4.1.3 Dial Mode Selection
Wink Signal Time-Out
Specifies the length of time that the PBX waits to receive a wink signal after seizing a CO line. If a wink signal
is not received before this timer expires, the CO line is released.
Default
1024 ms
Value Range
64 ´ n (n=1–128) ms
Maintenance Console Location
3.34 [1-1] Slot—Port Property - T1 Port
Programming Manual References
None
Feature Manual References
None
Start Signal Type
Selects the type of the start signal.
Default
Wink
Value Range
Immediate: Sends the dialed digits to the CO line when the First Dial Timer expires.
Wink: Sends the dialed digits to the CO line when the wink signal is received.
Maintenance Console Location
3.34 [1-1] Slot—Port Property - T1 Port
Programming Manual References
None
Feature Manual References
None
Document Version 2009-12
3.34 [1-1] Slot—Port Property - T1 Port
PC Programming Manual
291

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-ncp1000

Table of Contents