Siemens SINUMERIK 828D Function Manual page 750

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

K2: Axis Types, Coordinate Systems, Frames
10.5  Frames 
The following current system frames exist:
$P_SETFRAME
In the part program, the variable $P_SETFRAME can be used to read and write the current system frame for
PRESET and scratching. The variable returns a zero frame if the system frame is not configured through
MD28082.
$P_EXTFRAME
In the part program, the variable $P_EXTFRAME can be used to read and write the current system frame for
the zero offset external. The variable returns a zero frame if the system frame is not configured through
MD28082.
$P_PARTFRAME
In the part program, the variable $P_PARTFRAME can be used to read and write the current system frame for
TCARR and PAROT for toolholders with orientation capability. The variable returns a zero frame if the system
frame is not configured through MD28082.
$P_TOOLFRAME
In the part program, the variable $P_TOOLFRAME can be used to read and write the current system frame for
TOROT and TOFRAME. The variable returns a zero frame if the system frame is not configured through
MD28082.
$P_WPFRAME
In the part program, the variable $P_WPFRAME can be used to read and write the current system frame for
setting workpiece reference points. The variable returns a zero frame if the system frame is not configured
through MD28082.
$P_CYCFRAME
In the part program, the variable $P_CYCFRAME can be used to read and write the current system frame for
cycles. The variable returns a zero frame if the system frame is not configured through MD28082.
$P_TRAFRAME
In the part program, the variable $P_TRAFRAME can be used to read and write the current system frame for
transformations. The variable returns a zero frame if the system frame is not configured through MD28082.
$P_ISO1FRAME, $P_ISO2FRAME, $P_ISO3FRAME, $P_ISO4FRAME
One can read and write the current system frames for special ISO language commands in the parts program
through the variables. The variable returns a zero frame if the system frame is not configured through
MD28082.
$P_RELFRAME
In the part program, the variable $P_RELFRAME can be used to read and write the current system frame for
relative coordinate systems. The variable returns a zero frame if the system frame is not configured through
MD28082.
750
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents