230 VOLT 30A OR 50A WIRING
INSTRUCTIONS
(PALATINO, MARINO, & VANTO models only)
NOTE: The subpanel must be placed within 100 feet (30.5 m) of the
main electrical service panel, and between 5 feet (1.5 m) and 50 feet
(15 m) away from the spa. All electrical connections must be made in
accordance with the wiring information contained in this manual and on
the back of the field wiring access panel of the control box. When using
a 30A configuration, a CALDERA Spa Technician must reconfigure spa
using the soft jumpers to run heater at 4000K but Not run concurrent
with the jet pump.
CALDERA spas must be wired in accordance with all applicable local
electrical codes. All electrical work should be done by an experienced,
licensed electrician. We recommend the use of appropriate electrical
conduit, fittings, and wire for all circuits.
T h e e x a c t p h y s i c a l l o c a t i o n o f t h e t e r m i n a l s o n t h e G F C I b r e a k e r
w i l l v a r y b e t w e e n m a n u f a c t u r e r s . C o n n e c t i n g t h e h o t w i r e t o t h e
n e u t r a l t e r m i n a l w i l l c a u s e i r r e v e r s i b l e d a m a g e t o t h e c o n t r o l b o x .
230VAC, 50 Amp
2-POLE
CIRCUIT BREAKER
(NON GFCI)
#8 AWG WHITE, NEUTRAL
#8 AWG GREEN, GROUND
#8 AWG BLACK, L1
30/50A
#8 AWG RED, L2
MAIN SERVICE
ELECTRICAL
PANEL
*ALL CANADIAN SPA MODELS USE #8 AWG GREEN, GROUND.
THESE SPAS ARE INTENDED FOR USE WITH GFCI SUBPANEL
PROVIDED.
Electrical Requirements
2 3 0 VA C , 3 0 / 5 0 A , M O D E L S
L1
L2
GRD
LESS THAN 100 FT.
Page 5
W A R N I N G !
N
N, NEUTRAL, #8 AWG WHITE
30/50A
L2, HOT, #8 AWG RED
L1, HOT, #8 AWG BLACK
GROUND, #10 AWG GREEN*
SUBPANEL
MORE THAN 5 FEET
WITH GFCI
THE SUBPANEL MUST BE
BREAKERS
WITHIN SIGHT OF THE SPA
DO NOT EXCEED 50 FEET
CONTROL BOX
JUMPER CONFIGUR
J
J
J
J
FOR 230V SPA

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the vacanza series and is the answer not in the manual?

Questions and answers

Geno Mosier
March 20, 2025

I have 2017 vacanza tarino. The "+" button on my control panel is not responding, all the other buttons are working. I have already shut off the main power to reset it but that did not work.

1 comments:
Mr. Anderson
March 20, 2025

The manual does not provide specific troubleshooting for the "+" button not responding. However, you can try these general steps:

1. Check Power – Ensure the spa has power and is properly plugged in. Reset the GFCI if needed.
2. Inspect for Lock Mode – Some spa controls have a lock feature that may prevent button response. Check the manual for unlocking instructions.
3. Restart the Spa – Turn off the power at the breaker, wait a few minutes, then turn it back on.
4. Check for Debris or Damage – Inspect the button for dirt, debris, or physical damage.
5. Contact Authorized Service – If the button still does not work, contact an authorized CalderaSpas dealer or technician.

If the issue persists, professional service may be required.

This answer is automatically generated

Table of Contents