Alarm Options - MSA ALTAIR 5X Operating Manual

Multi gas detector
Hide thumbs Also See for ALTAIR 5X:
Table of Contents

Advertisement

Appendix – Flow Charts
7.6

Alarm Options

84
ALARM
OPTIONS
VIBRATOR
Press
HORN
Press
ALARM LEDS
Press
USER ACCESS TO
MOTION ALERT
Press
SENSOR ALARMS ?
Press
BACK TO SETUP ?
Press
RETURN TO
SETUP
ALTAIR 5X/ALTAIR 5X IR
TOGGLE
ON/OFF
Press
TOGGLE
ON/OFF
Press
TOGGLE
ON/OFF
Press
TOGGLE
ON/OFF
Press
SENSOR
ALARM SETUP
(See 7.6.2)
Press
MSA
GB

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALTAIR 5X and is the answer not in the manual?

Questions and answers

Steven Horak
January 27, 2025

What is the %volume function on the main screen? Do you have to equate this with the % LEL?

3 comments:
Michael Eisenbarth
January 31, 2025

@Steven Horak it is failing the ppm test. Im very unfamiliar with this device. Had it for about a yr and never had it failed.

Michael Eisenbarth
January 31, 2025

@Steven Horak failing the CO ppm test

Mr. Anderson
February 10, 2025

The % volume function on the MSA ALTAIR 5X main screen displays the concentration of combustible gases in volume percentage (% Vol). This function is relevant for infrared (IR) sensors measuring gases like propane, butane, and methane at high concentrations.

It relates to % Lower Explosive Limit (% LEL) in that:
- The device uses % LEL readings for combustible gas detection up to 100% LEL.
- If the environment contains more than 100% LEL of a combustible gas, the catalytic LEL sensor will enter a latching over-range alarm.
- In such cases, the IR sensors will switch from displaying % LEL to % Vol gas readings to provide accurate concentration data.

This ensures proper monitoring and safety in environments with high combustible gas concentrations.

This answer is automatically generated

Michael Eisenbarth
January 29, 2025

what would cause my device to fail the bump test

1 comments:
Mr. Anderson
February 10, 2025

The MSA ALTAIR 5X fails a Bump Test if the gas sensors are not functioning properly. If any installed sensor does not respond correctly to the test gas, the device will not display the √ symbol on the MEASURE page. Additionally, failure may indicate the need for a full calibration to ensure accuracy.

This answer is automatically generated

sherry
March 4, 2025

why does it keep beeping and reads underrande

1 comments:
Mr. Anderson
March 4, 2025

The MSA ALTAIR 5X may keep beeping and display "underrange" due to low battery warning or calibration issues. If the battery is low, the device will emit alarms and flash LEDs, and it should not be used until recharged. Additionally, environmental factors such as pressure, humidity, or incorrect calibration gas may cause sensor readings to fall below the expected range, triggering an underrange warning.

This answer is automatically generated

peter
March 6, 2025

the co alarm is 10.7. how to remove