Page 2
X·5 / XC·5 LED Strobe dimensions All dimensions in mm. Drawing not to scale.
Page 3
The SGM logo, the SGM name and all other trademar s in this document pertaining to ser ices or products by SGM or its af liates and subsidiaries are trademar s o ned or licensed by SGM or its af liates or subsidiaries.
Safety Information WARNING! This product is for professional use only! It is not for household use. Strobe lights are known to trigger epileptic seizures in persons who are photosensitive. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Page 6
• Provide a minimum clearance of 0.1 meters (4 inches) around air vents. • Do not modify the ture or install other than genuine SGM parts. • Do not operate the ture if the ambient air temperature (Ta) e ceeds 40 C (104 ).
AC Power Connection The auto-ranging power supply automatically adjusts to AC power from 208-240 volts nominal at 50/60 Hz. The current required by the X-5/XC-5 is 4 amps. To avoid overload, allow one 4 amp branch circuit per ture to operate the X-5/XC-5 model at full power.
Page 8
o rig t e t re Always use a secure means of secondary ing such as a safety wire Before installing; • Verify that the attachment hardware is in good condition and designed to carry at least 10 times the ture’s weight.
Data Connection The X-5/XC-5 provided 5-pin XLR connectors for data connection. The pin-out on all connectors is pin 1 to shield, pin 2 to cold (-), and pin 3 to hot (+). There is no connection to pins 4 and 5.
Setup ture uses an interactive display for setting up DMX address and operation mode. Use the ve buttons ne t to the display to navigate the setup structure (Fig. 1). Operation Data mode indicator Fig. 1 Fig. 2 Data Address protocol When the product is switched on, the ture will be at its default setting showing the ROOT menu (Fig.
Page 11
Setting DMX address In the root menu the user can set the DMX start address directly by using the arrow UP and DOWN (Fig. 3). Fig. 3 ture has a handy feature which displays the DMX start address for the ne t ture (assuming you are con- necting more than one ture)
(where it is always at ma imum intensity). A special pi el mode enables the ture to be used as a blinder, where the intensity of blinder colour (XC-5 models) or each of three pi el segments (X-5 models) can be set. Duration lash duration can be set from 0 to 650 ms on 50 Hz power supplies, or 0 to 530 ms on 60 Hz power supplies in 3, 4, 6 or 7 channel DMX modes.
Page 13
• Ramp up: Light gradually increases in intensity, then blacks out. • Ramp down: Light ashes to full intensity, then gradually fades. • Ramp up-down: Light gradually increases and decreases. • Random ash: Light ashes randomly with variable rate and intensity. Multiple units ash independently of each other. •...
Disconnect the product from the main power for at least 1 minute before servicing. Fuse Replacement The X-5/XC-5 uses a time-delay fuse for protection against current overload. The fuse is located inside the base on the main PC of the ture ne t to the low voltage power supply.
DMX Protocols 1 channel mode Channel Value Percent Function Blackout 6-249 2-97 lash rate, slow to fast 250-255 98-100 Continuous blinder effect 3 channel mode Channel Value Percent Function Blackout 6-255 2-100 lash intensity - minimum to ma imum lash duration: 0-255 0-100 0-650 ms @ 50 Hz AC...
Page 16
4 channel mode Channel Value Percent Function Blackout 6-255 2-100 lash intensity - minimum to ma imum lash duration: 0-255 0-100 0-650 ms @ 50 Hz AC 0-530 ms @ 60 Hz AC No ash (trigger single ash using channel 1) lash rate: 6-255 2-100...
Page 17
6-255 2-100 lash intensity - minimum to ma imum Blackout Red blinder intensity (XC-5 models), or 6-255 2-100 Segment 1 intensity (X-5 models) Blackout Green blinder intensity (XC-5 models), or 6-255 2-100 Segment 2 intensity (X-5 models) Blackout Blue blinder intensity (XC-5 models), or...
Page 18
7 channel mode Channel Value Percent Function Blackout 6-255 2-100 lash intensity - minimum to ma imum lash duration: 0-255 0-100 0-650 ms @ 50 Hz AC 0-530 ms @ 60 Hz AC No ash (trigger single ash using channel 1) lash rate: 6-255 2-100...
Page 19
Blackout Green blinder intensity (XC-5 models), or 6-255 2-100 Segment 2 intensity (X-5 models) Blackout Green blinder intensity (XC-5 models), or 6-255 2-100 Segment 2 intensity (X-5 models) Blackout Blue blinder intensity (XC-5 models), or 6-255 2-100 Segment 3 intensity (X-5 models)
6-255 2-100 lash intensity - minimum to ma imum Blackout Red blinder intensity (XC-5 models), or 6-255 2-100 Segment 1 intensity (X-5 models) Blackout Green blinder intensity (XC-5 models), or 6-255 2-100 Segment 2 intensity (X-5 models) Blackout Blue blinder intensity (XC-5 models), or...
Page 21
Channel Value Percent Blinder intensity Blackout Red blinder intensity (XC-5 models), or 6-255 2-100 Segment 1 intensity (X-5 models) Blackout Green blinder intensity (XC-5 models), or 6-255 2-100 Segment 2 intensity (X-5 models) Blackout Blue blinder intensity (XC-5 models), or...
Page 22
Speci cations X·5 (Part #: 80090001) XC·5 (Part #: 80090002) PHYSICAL Size (without bracket) ..............120 mm Weight (without brackets / Cables)……………………………………............……5.8 kg THERMAL Ma imum ambient temperature……………………………...............40 C (104 CONTROL AND PROGRAMMING USITT DMX512-A control……….........1, 3, 4, 6, 7 and 7 channel Legacy modes, pi el mode (3 channels) AC POWER AC input……………………………………………………………..............Powercon Approved AC power (EU)…………………..............208 - 240 V nominal, 50/60 Hz...
Page 23
CONSTRUCTION Housing……………………………………………………………..........Aluminium inish…………………………………………..............Electrostatic powder coating INSTALLATION Minimum clearance around fan and air vents…………………..............0.1 m (4 in) APPROVALS AND CERTIFICATIONS Certi ed to..........................CSA Std. C22.2 No. 166 Conforms to.............................UL Std. 1573 Conforms to........................2004/108/EC: EMC Directive Conforms to......................2006/95/EC: Low Voltage Directive Conforms to........................2011/65/EU: RoHS2 Directive peci cation ect to c ange wit o t notice RoHS...
Need help?
Do you have a question about the X-5 and is the answer not in the manual?
Questions and answers