2 SEL-787 Relay Command Summary
Serial Port Command
EVE DIF1 n
EVE DIF2 n
EVE DIF3 n
EVE R n
FIL DIR
FIL READ filename
FIL SHOW filename
GOO k
GRO
HEL
HIS n
HIS C or R
IRIG
LDP
LDP C
MAC
MET
MET k
MET AI
MET DEM k
MET DIF k
MET E
MET H
MET M
MET MV
MET PEA k
MET PM
MET RD
MET RE
MET RM
MET RMS
MET RP
MET T
SEL-787 Relay
Show differential element 1 event report number n, with 1/4-cycle resolution.
Show differential element 2 event report number n, with 1/4-cycle resolution.
Show differential element 3 event report number n, with 1/4-cycle resolution.
Show raw analog data event report number n, with 1/16-cycle resolution, same as EVE n R.
Return a list of files.
Transfer settings file filename from the relay to the PC.
Filename 1 displays contents of the file filename.
Display transmit and receive GOOSE messaging information. Enter number k to scroll the GOOSE data k
times on the screen.
Display active group setting.
Display a short description of selected commands.
Show summary of n latest event reports, where n = 1 is the most recent entry. If n is not specified, all event
report summaries are displayed.
Clear or reset history buffer.
Force synchronization of internal control clock to IRIG-B time-code input.
Display signal profile data.
Clear signal profile data.
Display the MAC address of the Ethernet
Display fundamental metering data. (Can also use MET F.)
Display fundamental metering data k times, where k is between 1 and 32767.
Display analog input (transducer) data.
Display demand metering data, in primary amperes. Enter number k to scroll metering k times on screen.
Display differential metering data. Enter number k to scroll metering k times on screen.
Display energy metering data.
Generate harmonic report for all input currents and voltages, showing first- to fifth-harmonic levels and
%THD (total harmonic distortion).
Display minimum and maximum metering data.
Display SEL
math variable data.
OGIC
Display peak demand metering data, in primary amperes. Enter number k to scroll metering k times on
screen.
Display synchrophasor metering data.
Reset demand metering values.
Reset energy metering data.
Reset minimum and maximum metering data.
Display RMS metering data.
Reset peak demand metering values.
Display RTD metering data.
Instruction Manual
Command Description
®
port (PORT 1).
Date Code 20150130
Need help?
Do you have a question about the SEL-787 and is the answer not in the manual?
Questions and answers
I need to get a manual in order to how select a relay 787, I want to select SEL 0787EX1X1A9X75850231