5.04 Fault Indicator

At initial power up, two lights will temporarily illuminate for 2-3 seconds to show the version of software used.
To determine the first digit, count the function indicators left to right, 1 through 5. To determine the second digit
count the pressure indicators, reading from bottom to top, 0 through 7. In the example below the Temp indicator
and 75 psi indicators are on indicating the version would be 2.3.
7
6
5
A
MAX
MIN
PSI
MAX
4
3
2
1
MIN
0
!
1 2 3 4
5
!
When the "Fault" indicator is ON or blinking it will be accompanied by one of the pressure indicator lights
depending on what the Fault is. The following table explains each of those Faults.
NOTE!
Fault explanations are covered in the following tables.
Manual 0-5396
BAR
MAX
+
MIN
Art# A-07988
Pressure
Fault
Indicator
Max
Over Pressure
90
Internal Error
85
Check Consumables
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure