AR-FX2
SW
Data
Item
NO.
NO.
SW2
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Remote select
No. setup
6
7
8
SW3
1
Density default
setup
2
3
4
5
6
Reserved
7
Size
specification
8
SW4
1
Recall interval
in case of a
2
communication
3
error
4
5
Recall interval
in case of
6
busy state
7
8
Switch selection and contents of functions
Used to set the number for remote select reception from
an external telephone with binary input. However, the
remote select numbers "x∗" and "∗" are fixed.
For an input over "10", the same operation as the initial
value of "5" is performed.
SW2 Bit No.
1 2 3 4 5 6 7 8
Set range
0 – 9 (Binary input)
Used to set the density (LED) after pressing C/A key or
in auto clear operation to Auto, Light, Slightly light,
Medium, Slightly data, and Dark.
SW Bit No.
1 2 3 4 5
Auto
0 0 0 0 0
Light
1 0 0 0 0
Slightly light
0 1 0 0 0
Medium
0 0 1 0 0
Slightly dark
0 0 0 1 0
Dark
0 0 0 0 1
Used to set the source of judgement of size specification
(AB series or inch series).
SW Bit No.
7 8
Inch size
1 0
Follows the machine
0 1
information.
Follows the machine
1 1
information.
Used to set recall interval after disconnection of
communication due to a communication error in memory
transmission. The set range is 0 to 15 min in the
increment of 1 min by binary input. When set to 0, recall
is made immediately after disconnection. However, the
time interval set by SW21 (Interval between the end of a
communication and the next call) is taken.
SW4 Bit No.
1 2 3 4
0 – 15 (Binary
Set value
input)
Used to set recall interval after disconnection of
communication due to the busy state of the other party
or no response. The set range is 0 to 15 min in the
increment of 1 min by binary input. When set to 0, recall
is made after 3 min.
SW4 Bit No.
5 6 7 8
Set value
0 – 15 (Binary input)
Initial value
5
Auto
Follows
the
machine
If the machine
informa-
information is
tion.
uncertain when set
to "Follows the
machine information",
the metric size is
effective.
1 min
0: Immediate
recall after
disconnection.
3 min
6 – 2
User
program
Remark
No.
0
0
0
0
0
108
When a value
in the range of
1
10 – 15 is set,
0
set to "5."
1
153
0
0
0
0
0
1
0
113
0
0
1
0
111
When "0000" is
tried to be set,
0
"0011" is set.
1
1