reset
reset
Use this command to reset the switch without losing any user‐defined configuration settings.
Syntax
reset [unit]
Parameters
unit
Defaults
If no unit ID is specified, the entire system will be reset.
Mode
Switch command, read‐write.
Usage
A Enterasys B5 switch can also be reset with the RESET button located on its front panel. For
information on how to do this, refer to the Enterasys B5 Installation Guide shipped with your
switch.
Examples
This example shows how to reset the system:
B5(su)->reset
Are you sure you want to reload the stack? (y/n) y
Saving Configuration to stacking members
Reloading all switches.
This example shows how to reset unit 1:
B5(su)->reset 1
Are you sure you want to reload the switch? (y/n) y
Reloading switch 1.
This switch is manager of the stack.
STACK: detach 3 units
clear config
Use this command to clear the user‐defined configuration parameters.
Syntax
clear config [all]
Parameters
all
3-50 Basic Configuration
(Optional) Specifies a unit to be reset.
(Optional) Clears user‐defined configuration parameters (and stack unit
numbers and priorities, if applicable).