TABLE OF CONTENTS Before using the Monitor Introduction ......................3 Safety information....................4 Intended use....................4 General usage ..................4 General usage ..................5 Battery usage ..................5 General precautions................6 Operating Instructions Before taking a measurement ..................7 Know your unit......................8 Unit display ......................9 Display symbols ....................10 Irregular heartbeat symbol..............10 Movement error symbol ...............10 Average reading symbol...............10...
INTRODUCTION Thank you for purchasing the ReliOn BP300W Wrist Blood Pressure Monitor, Model # 6021RELN2. Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ • Staple your purchase receipt here The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure.
SAFETY INFORMATION INTENDED USE This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population. The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with the readings. To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
SAFETY INFORMATION GENERAL USAGE Always consult your physician. Self-diagnosis of measurement values and self-treatment are dangerous. Consult your physician before using the device for any of the following conditions: • If you have had a mastectomy. • If you have a condition that may compromise circulation, you may get an inaccurate reading with this device.
SAFETY INFORMATION GENERAL PRECAUTIONS • Store the device and the components in a clean, safe location. • Do not drop the monitor or subject device to strong shocks or vibrations. • Do not submerge the device or any of the components in water. •...
BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 5 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid taking measurements during stressful times. 3.
UNIT DISPLAY Blood pressure Date/Time display level indicator User symbol (A or B) (High/Normal) Memory symbol Deflation symbol Movement error symbol Average reading symbol Systolic blood pressure Irregular heartbeat symbol Heartbeat symbol Diastolic blood (Flashes during pressure measurement) Battery symbol (low/depleted) Positioning indicator symbol Pulse display and...
DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a Normal Heartbeat rhythm that varies by 25% less or 25% more than Pulse...
Page 11
DISPLAY SYMBOLS 2013 ESH/ESC Guidelines for the management of arterial hypertension Definitions of hypertension by office and home blood pressure levels Office Home Systolic Blood Pressure ≥ 140 mmHg ≥ 135 mmHg Diastolic Blood Pressure ≥ 90 mmHg ≥ 85 mmHg These are from statistical values for blood pressure.
BATTERY INSTALLATION 1. Press the indicator on two sides of the battery cover and slide the cover off in the direction of the arrow. 2. Install 2 “AAA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
SETTING THE DATE AND TIME Set the monitor to the correct date and time before taking a measurement for the first time or after replacing the batteries. 1. Press and hold the button until the year flashes on the display. 2.
SETTING THE POSITIONING INDICATOR The monitor has a built-in positioning indicator that is used as an aid in determining if the monitor is at the correct height. When using this positioning indicator, the distance from the top of your seat measuring to the top of the table you are sitting at, should be 12 ±...
APPLYING THE WRIST CUFF APPLYING THE CUFF ON THE LEFT WRIST 1. Roll up sleeve. Make sure your sleeve is not rolled up too tightly on your arm. This may constrict the flow of blood in your arm. 2. Put your arm through the cuff loop. Your palm should face upward.
TAKING A MEASUREMENT The monitor is designed to store the blood pressure and the pulse rate in the memory for two people (user A or user B) every time a measurement is completed. 1. Sit comfortably with the elbow of the arm being measured resting on a table and elevate cuff wrist to heart level.
Page 17
TAKING A MEASUREMENT The monitor is in The monitor is higher The monitor is lower proper position. than the heart and than the heart and needs needs to be lowered. to be raised. As the cuff inflates, the monitor automatically determines your ideal inflation level.
USING THE MEMORY FUNCTION The monitor automatically stores the results up to 90 sets for each user (A and B). It can also calculate an average reading based on the last 3 measurement values taken within 10 minutes. TO VIEW THE MEASUREMENT VALUES STORED IN MEMORY 1.
USING THE MEMORY FUNCTION TO VIEW THE AVERAGE READING 1. Select the user ID (A or B). 2. While display off or just completing a measurement, press and hold the Memory button for more than 3 seconds. NOTES: • If the previous measurement was taken without setting the date and time, the average reading is not calculated.
CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Do not forcefully bend the cuff. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use any abrasive or harsh cleaners such as bleach.
ERROR INDICATORS SYMBOL CAUSE CORRECTION Remove the arm cuff. Wait 2-3 minutes and Irregular heartbeats are then take another measurement. Repeat the steps in “Taking a Measurement”. If this detected. error continues to appear, contact your physician. Remain still and do not talk during the Movement during measurement.
TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS Replace both batteries with new ones at the same No power. time. Check the battery installation for proper No display appears on the unit. placement of the battery polarities. Blood pressure varies constantly. Many factors including stress, time of day, how you wrap the Measurement values appear too cuff, may affect your blood pressure.
FCC STATEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY. RELION SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES. This warranty provides you with specific legal rights, and you may have other rights which vary from state to state.
IEC60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: • The use of accessories and cables other than those specified by ReliOn, with the exception of cables sold by ReliOn as replacement parts for internal components, may result in increased emission or decreased immunity of the device.
Page 27
(Table 1) Guidance and manufacturer’s declaration – electromagnetic emissions ReliOn 6021RELN2 is intended for use in the electromagnetic environment specified below. The customer or the user of this ReliOn 6021RELN2 should assure that it is used in such environment. Electromagnetic environment...
Page 28
(Table 2) Guidance and manufacturer’s declaration – electromagnetic immunity ReliOn 6021RELN2 is intended for use in the electromagnetic environment specified below. The customer or the user of this ReliOn 6021RELN2 should assure that it is used in such environment. IEC 60601...
Page 29
GUIDANCE AND MANUFACTURER’S DECLARATION IEC 60601 Compliance Electromagnetic environment Immunity test Test level level – guidance <5 % U (>95 % dip in U for 0.5 cycle 40 % U Voltage dips, (60 % dip in short interruptions for 5 cycles and voltage Not Applicable.
Page 30
(Table 4) Guidance and manufacturer’s declaration – electromagnetic immunity ReliOn 6021RELN2 is intended for use in the electromagnetic environment specified below. The customer or the user of this ReliOn 6021RELN2 should assure that it is used in such environment. IEC 60601...
Page 31
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the ReliOn 6021RELN2 is used exceeds the applicable RF compliance level above, the ReliOn 6021RELN2 should be observed to verify normal operation.
Page 32
GUIDANCE AND MANUFACTURER’S DECLARATION (Table 6) Recommended separation distance between portable and mobile RF communications equipment and the ReliOn 6021RELN2 ReliOn 6021RELN2 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this...