Installation Instructions
NOTE:
Read
the entire
instruction
manual
before
starting
the
installation.
TABLE
OF CONTENTS
PAGE
SAFETY
CONSIDERATIONS
........................
1
INTRODUCTION
..................................
1
HEATER
PACKAGES
..............................
2
INSTALLATION ...................................
2
Step 1 -- Check Equipment
.........................
2
Step 2 -- Mount Unit
..............................
2
Step 3 -- Air Ducts
...............................
4
Step 4 -- Electrical
Connections
.....................
4
Step 5 -- Refrigerant
Tubing
Connection
and Evacuation
..
7
Step 6 -- Refrigerant
Flow-Control
Device
.............
7
Step 7 -- Condensate
Drains
........................
8
Step 8 -- Accessories
..............................
9
Step 9 -- Sequence
of Operation
....................
10
START-UP
PROCEDURES
.........................
10
CARE AND MAINTENANCE
.......................
10
AIRFLOW
PERFORMANCE
TABLES
................
11
SAFETY
CONSIDERATIONS
Improper
installation,
adjustment,
alteration,
service,
maintenance,
or use
can
cause
explosion,
fire,
electrical
shock,
or
other
conditions
which
may
cause
death,
personal
injury
or property
damage.
Consult
a qualified
installer,
service
agency,
or your
distributor
or branch
for information
or assistance.
The qualified
installer
or agency
must use factory-authorized
kits or accessories
when modifying
this product.
Refer to the individual
instructions
packaged
with kits or accessories
when installing.
Follow
all safety
codes.
Wear safety
glasses,
protective
clothing
and work
gloves.
Have
a fire extinguisher
available.
Read
these
instructions
thoroughly
and
follow
all
warnings
or
cautions
included
in literature
and
attached
to the
unit.
Consult
local
building
codes
and the current
editions
of the National
Electrical
Code (NEC) NFPA 70.
In Canada,
refer to the current
editions
of the Canadian
Electrical
Code CSA C22A.
Recognize
safety information.
This is the safety-alert
symbol
/_.
When you see this symbol
on the unit and in instruction
manuals,
be alert to the potential
for personal
injury.
Understand
the
signal
words
DANGER,
WARNING,
and
CAUTION.
These words
are used with
the safety-alert
symbol.
DANGER
identifies
the most serious
hazards
which
will result in
severe
personal
injury
or death.
WARNING
signifies
hazards
which
could result
in personal
injury or death. CAUTION
is used
to identify
unsafe
practices
which
may result
in minor
personal
injury or product
and property
damage.
NOTE
is used to highlight
suggestions
which will result in enhanced
installation,
reliability,
or
operation.
ELECTRICAL
OPERATION
HAZARD
Failure
to follow
this warning
could
result
in personal
injury
or death.
Before
installing
or servicing
unit, always
turn off all power
to
unit.
There
may be more
than 1 disconnect
switch.
Turn
off
accessory
heater power
if applicable.
Lock out and tag switch
with a suitable warning
label.
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs, Use care and
wear
appropriate
protective
clothing
and
gloves
when
handling parts,
INTRODUCTION
Models
FB4C
and
FY5B
are
Puron
Fan
Coils
designed
for
installation
flexibility.
These units are designed
to meet the low air
leak requirements
currently
in effect.
FB4C
uses
a refrigerant
piston
metering
device
with
an X-13
integral
electronically
commutated
motor
for efficiency.
These
units
have
be designed
for upflow,
downflow
(kit required),
and
horizontal
orientations,
including
manufactured
and mobile
home
applications.
FY5B
uses a refrigerant
piston metering
device (018 thru 048) with
2-speed
PSC
(permanent
split capacitor)
motors
and TXV
with
3-speed
PSC motor
for the 060 size, These units
can be used for
upflow
or
downflow
(kit
required)
orientations,
including
manufactured
and mobile
homes
applications.
These
units
require
a field supplied
air filter,
and are designed
specifically
for Puron
refrigerant
air conditioners
and heat pumps
as shipped.
These units are available
for systems
of 18,000
through
60,000
Btuh nominal
cooling
capacity.
Factory-authorized,
field -
installed
electric
heater
packages
are available
in sizes 5 through
30kW.
See Product
Data literature
for all available
accessory
kits.
Need help?