How To Clear The History - Pioneer PDP4360HD Product Training Manual

6th generation plasma models
Hide thumbs Also See for PDP4360HD:
Table of Contents

Advertisement

HOW TO CLEAR THE HISTORY

Clearing data on various histories when the HD DIGITAL Assy is replaced
Other than adjustment data for the main unit, data to be backed up include the accumulated power-on time and a history of defective parts,
which are data updated and stored in memory. Among those data, some are required to be cleared when the HD DIGITAL Assy is replaced
for servicing, as shown below:
Item
Backed-up data
Hour meter
Accumulated display
Point where an SD
occurred and data on the
SD history
hour meter
Point where a PD
occurred and data on the
PD history
hour meter
Accumulated number of
pulses of the Panel (5
Pulse meter
blocks)
Accumulated number
Accumulated number of
of power-ons
RELAY_ONs
Notes:
1: With the PDP-506P/436P and subsequent models, because various compensation functions use pulse-meter data for calculating
compensation values, if related Assys are replaced, data on various histories must be cleared.
2: To clear data using RS-232C commands, after entering Factory mode (by sending FAY or PFY), issue a corresponding command.
Otherwise, the command will not be executed.
How to clear the history for each item on the Factory Menu
Clearing the PD history
Clearing the SD history
Clearing the data on the
hour meter
Clearing the data on the
pulse meter
Clearing the data on the
number of power-ons
Type of servicing
Panel
Replacement of the
replacement
power-supply block
To be cleared
To be cleared
To be cleared
To be cleared
(essential)
Not to be
cleared
Start point of Panel Factory
PANEL INFORMATION
∞ (down)
• • •
∞ (down)
ETC. (+)
[set]
BACKUP DATA
∞ (down)
DIGITAL EEPROM
∞ (down)
PD INFO: NO OPRT
∞ (down)
SD INFO: NO OPRT
∞ (down)
HR-MTR INFO: NO OPRT
∞ (down)
PM/B1-BS INFO: NO OPRT
∞ (down)
P COUNT INFO: NO OPRT
47
Others
Not to be
Not to be cleared
cleared
Not to be
Not to be cleared
cleared
Not to be
Not to be cleared
cleared
Not to be
Not to be cleared
cleared
Not to be
To be cleared
cleared
(essential)
>> (right)
PD INFO: CLEAR
[set] (Press and hold for 5 seconds.)
>> (right)
SD INFO: CLEAR
[set] (Press and hold for 5 seconds.)
>> (right)
HR-MTR INFO: CLEAR
[set] (Press and hold for 5 seconds.)
>> (right)
PM/B1-BS INFO: CLEAR
[set] (Press and hold for 5 seconds.)
>> (right)
P COUNT INFO: CLEAR
[set] (Press and hold for 5 seconds.)
RS-232C
command
CHM
CSD
CPD
CPM
CPC

Hide quick links: