Specifications - Kenwood pds20-18 Service Manual

Regulated dc power supply
Table of Contents

Advertisement

Model name
Rated output voltage (V)
Rated output current (A)
Output
Output voltage range (V)
Output current range (A)
Rated output power (W)
Constant voltage characteristics
Power regulation
Load regulation
Ripple noise, p-p
(Measured with 20 MHz oscilloscope)
Ripple noise, rms (5 Hz – 1 MHz)
Transient response (typ.)
Temperature coefficient (typ.)
Rise time (typ.)
Fall time (typ.)
Analog remote control setting accuracy
(IF 30AN optional board is used)
External voltage (+ curve) : 0 to 10V
External voltage (- curve) : 10 to 0V
External resistance (+ curve) : 0 to 10kΩ
External resistance (- curve) :10k to 0Ω
Constant current characteristics
Power regulation
Load regulation
Ripple noise, rms (5 Hz – 1MHz)
Temperature coefficient (typ.)
Analog remote control setting accuracy
(IF 30A optional board is used)
External voltage (+ curve) : 0 to 10V
External voltage (- curve) : 10 to 0V
External resistance (+ curve) : 0 to 10kΩ
External resistance (- curve) :10k to 0Ω
Meter and display
Display & accuracy
Voltmeter
(23 5°C)
Min. reading
Display & accuracy
Ammeter
(23 5°C)
Min. reading
In constant voltage operation
In constant current operation
Output ON indicator
PDS20-18/PDS36-10/PDS60-6

SPECIFICATIONS

PDS20-18
20
18
0-20
0-18
0.005% +1 mV (for
0.005% +2mV (for 0 to 100% fluctuation)
1mVrms
Full load/no 100 msec/100msec
Full load/no load 150msec/1000msec
5mA
10mArms
4 digits, LED, 0.1% rdg
4 digits, LED, 0.5% rdg
PDS36-10
36
10
0-36
0-10
360
10% source voltage fluctuation)
30 mVp-p
1 mVrms
100 µsec
100 ppm/°C
3% 50mV
3% 100mV
1mA
5mA
5mArms
100ppm/°C
3% 50mA
3% 100mA
2 digits
0.1% rdg
10mV
2 digits
0.5% rdg
10mA
CV LED is lit.
CC LED is lit.
OUTPUT LED is lit.
PDS60-6
60
6
0-60
0-6
3 digits, LED,
2 digits
100 mV
3 digits, LED,
2 digits
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pds36-10Pds60-6

Table of Contents