Samsung AR09KSWSJWKNCV Service Manual page 96

Hide thumbs Also See for AR09KSWSJWKNCV:
Table of Contents

Advertisement

10-2-16 DC_link voltage under/over error, H/W DC-link Over voltage protection error/PFC over load
Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the input voltage of outdoor terminal block is normal?
2) Is the input voltage is higher than 300Vac?
3) Is the reactor wire connected?
4) Is the DC_link capacitor(A") assembled in accordance the specification? (Outdoor PBA)
5) Is the DC_link resistor("B") value is normal? (Outdoor PBA)
6) Is the PFC resistor("C") value is normal? (Outdoor PBA)
2. Troubleshooting procedure
Is the connected of reactor wire?
Is the the input voltage is nomal?
Normal range(180Vac 270Vac)
Start the operation (cooling mode or heating mode)
("A") is normal in operation mode?
Normal range(280Vdc 320Vdc)
10-18
LED3
LED OFF
(PBA-Reactor)
YES
Restart after power off.
YES
Restart after power off.
Is the DC_link voltage
YES
7-SEG DISPLAY
E466
E483
E484
DC-Link voltage under/over error
PFC over load
Over Voltage Protection Erro
MODEL
AR12(09)HSFSHWK
AR18HSFSHWK
AR24HSFSHWK
MODEL
AR12(09)HSFSHWK
AR18HSFSHWK
AR24HSFSHWK
NO
Connect the reactor wire
NO
Check the input power in the powercord.
NO
Check the input power
DESCRIPTION
DC-Link voltage under/over error
Over Voltage Protection Error
PFC over load
"A"
CE101,CE102,CE103
R101,R102,R103,R104
CE001,CE002,CE003,CE004
R004,R005,R006,R007
C141,C142,C143,C144
"C"
R105,R106,R107,R108
"-"
"-"
Samsung Electronics
"B"
R141-R147
"D"
R101,R105
R004
R146