Split-type room air conditioner (cool and heat) (26 pages)
Summary of Contents for Samsung Max Heat 2.0
Page 1
Technical Data Book RAC for North America (INV, R410A, 60Hz, HP) Model : AR**TSF*BWKNCV (Indoor Unit) AR**TSF**WKXCV (Outdoor Unit)
Page 2
Modification Date Remark Released RAC for North America Ver.1.0 19. 12. 20 (Wind-Free 2.0, Quantum 2.0, Max Heat 2.0) Ver.1.1 Updated Model Name including US Code 20. 01. 29 Ver.1.2 Updated the power data (MCA/MOP) in specification pages 20. 02. 14 Ver.1.3...
Page 3
Nomenclature Model Name Buyer (1) Classification (6) Design Segment Wind-Free™ 2.0 Quantum 2.0 (2) Capacity (7) Version x1000 Btu/h A-Z (1 digit) (3) Year (8) Color 2020 DA White (9) Set (4) Product Type Indoor Unit INVERTER HP R410A Outdoor Unit (5) Characteristics Motion Detect Sensor +Wi-Fi + Tri-care Filter...
Page 4
Line-up Indoor Unit Model Type Design Image Max Heat 2.0 Wind-Free Wind-Free™ 2.0 Quantum 2.0 Capacity (kBtu/h) Model Type Design Max Heat 2.0 Wind-Free Wind-Free™ 2.0 Quantum 2.0...
Page 5
Line-up Outdoor Unit Capacity (kW) Model Type Design Max Heat 2.0 Wind-Free Wind-Free™ 2.0 Quantum 2.0...
Page 6
Contents 1. Specification 2. Capacity Table 3. Dimensional Drawing 4. Center of Gravity 5. Electrical Wiring Diagram 6. Sound Data 7. Temperature and air flow distribution 8. Piping Diagram 9. Operation Limit 10. Capacity Correction 11. Installation...
Page 7
1. Specification 1. Specification Quantum 2.0 AR09TSFYBWKNCV AR12TSFYBWKNCV AR18TSFYBWKNCV AR24TSFYBWKNCV Indoor Unit Model Name AR09TSFYBWKXCV AR12TSFYBWKXCV AR18TSFYBWKXCV AR24TSFYBWKXCV Outdoor Unit RNS09YBT RNS12YBT RNS18YBT RNS24YBT Indoor Unit US Code RXS09YBT RXS12YBT RXS18YBT RXS24YBT Outdoor Unit HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Mode 0.88 / 2.64 / 3.52...
Page 8
1. Specification Quantum 2.0 AR09TSFYBWKNCV AR12TSFYBWKNCV AR18TSFYBWKNCV AR24TSFYBWKNCV Indoor Unit Model Name AR09TSFYBWKXCV AR12TSFYBWKXCV AR18TSFYBWKXCV AR24TSFYBWKXCV Outdoor Unit RNS09YBT RNS12YBT RNS18YBT RNS24YBT Indoor Unit US Code RXS09YBT RXS12YBT RXS18YBT RXS24YBT Outdoor Unit Removable / Washable Removable / Washable Removable / Washable Removable / Washable Easy Filter Plus Additional...
Page 9
1. Specification Wind-Free™ 2.0 AR09TSFABWKNCV AR12TSFABWKNCV AR18TSFABWKNCV AR24TSFABWKNCV Indoor Unit Model Name AR09TSFABWKXCV AR12TSFABWKXCV AR18TSFABWKXCV AR24TSFABWKXCV Outdoor Unit RNS09ABT RNS12ABT RNS18ABT RNS24ABT Indoor Unit US Code RXS09ABT RXS12ABT RXS18ABT RXS24ABT Outdoor Unit HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Mode 0.88 / 2.64 / 3.81 0.88 / 3.52 / 4.4...
Page 10
1. Specification Wind-Free™ 2.0 AR09TSFABWKNCV AR12TSFABWKNCV AR18TSFABWKNCV AR24TSFABWKNCV Indoor Unit Model Name AR09TSFABWKXCV AR12TSFABWKXCV AR18TSFABWKXCV AR24TSFABWKXCV Outdoor Unit RNS09ABT RNS12ABT RNS18ABT RNS24ABT Indoor Unit US Code RXS09ABT RXS12ABT RXS18ABT RXS24ABT Outdoor Unit Removable / Washable Removable / Washable Removable / Washable Removable / Washable Easy Filter Plus Additional...
Page 11
1. Specification Max Heat 2.0 AR09TSFABWKNCV AR12TSFABWKNCV AR18TSFABWKNCV AR24TSFABWKNCV Indoor Unit Model Name AR09TSFACWKXCV AR12TSFACWKXCV AR18TSFACWKXCV AR24TSFACWKXCV Outdoor Unit RNS09ABT RNS12ABT RNS18ABT RNS24ABT Indoor Unit US Code RXS09ACT RXS12ACT RXS18ACT RXS24ACT Outdoor Unit HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP Mode 0.88 / 2.64 / 3.81...
Page 12
1. Specification Max Heat 2.0 AR09TSFABWKNCV AR12TSFABWKNCV AR18TSFABWKNCV AR24TSFABWKNCV Indoor Unit Model Name AR09TSFACWKXCV AR12TSFACWKXCV AR18TSFACWKXCV AR24TSFACWKXCV Outdoor Unit RNS09ABT RNS12ABT RNS18ABT RNS24ABT Indoor Unit US Code RXS09ACT RXS12ACT RXS18ACT RXS24ACT Outdoor Unit Removable / Washable Removable / Washable Removable / Washable...
Page 42
6. Sound Data Outdoor units : Max Heat 2.0 Sound Pressure level Unit: dB(A) Model Cooling RXS09ACT (AR09TSFACWKXCV) Microphone RXS12ACT (AR12TSFACWKXCV) RXS18ACT (AR18TSFACWKXCV) RXS24ACT (AR24TSFACWKXCV) Front • NC Curve 1) RXS09ACT (AR09TSFACWKXCV) 2) RXS12ACT (AR12TSFACWKXCV) 3) RXS18ACT (AR18TSFACWKXCV) 4) RXS24ACT (AR24TSFACWKXCV) NOTE •...
Page 43
7. Temperature and air flow distribution Quantum 2.0 RNS09YBT (AR09TSFYBWKNCV) • Cooling air velocity distribution • Cooling Temperature distribution (Discharge angle : 20 degree) (Discharge angle : 20 degree) • Heating air velocity distribution • Heating Temperature distribution (Discharge angle : 30 degree) (Discharge angle : 30 degree) RNS12YBT (AR12TSFYBWKNCV) •...
Page 44
7. Temperature and air flow distribution Quantum 2.0 RNS18YBT (AR18TSFYBWKNCV) • Cooling air velocity distribution • Cooling Temperature distribution (Discharge angle : 20 degree) (Discharge angle : 20 degree) • Heating air velocity distribution • Heating Temperature distribution (Discharge angle : 30 degree) (Discharge angle : 30 degree) RNS24YBT (AR24TSFYBWKNCV) •...
Page 45
7. Temperature and air flow distribution Max Heat 2.0 / Wind-Free™ 2.0 RNS09ABT (AR09TSFABWKNCV) • Cooling air velocity distribution • Cooling Temperature distribution (Discharge angle : 20 degree) (Discharge angle : 20 degree) • Heating air velocity distribution • Heating Temperature distribution...
Page 46
7. Temperature and air flow distribution Max Heat 2.0 / Wind-Free™ 2.0 RNS18ABT (AR18TSFABWKNCV) • Cooling air velocity distribution • Cooling Temperature distribution (Discharge angle : 20 degree) (Discharge angle : 20 degree) • Heating air velocity distribution • Heating Temperature distribution...
Page 47
8. Piping Diagram OUTDOOR UNIT INDOOR UNIT Thermistor - Thermistor- IDU Heat Exchager Mid Heat (T_IM) Exchanger (T_II) Service Valve- Heat Exchanger - Gas Pipe Indoor unit (SV_G) (HX_ID) Outdoor Fan Motor (OFM) Indoor Thermistor- Fan Motor Indoor Room (IFM) Electronic (T_IR) Thermistor-...
Page 48
Warming Operation Range Operation Operation Range Range -5.08 60.8 60.8 89.6 Indoor Temperature ( Indoor Temperature ( Max Heat 2.0 : RNS**ABT+RXS**ACT (AR**TSFABWKNCV+AR**TSFACWKXCV) Cooling Heating 75.2 114.8 Warming Operation Range Operation Operation Range Range -0.4 50 55 60 65 70 75 80 85 90 95 100 60.8...
Page 51
11. Installation Viewing the typical installation A typical installation will be similar to the one shown below. Evaporator/fancoil (indoor) Maximum pipe height Refrigerant lines, electric, and drain Maximum pipe length Compressor/condenser(outdoor) Unit : ft (m) Pipe length Pipe height Model Standard for factory Minimum Maximum...
Page 52
11. Installation Choosing the installation location Indoor unit location requirements WARNING installation manual supplied with the outdoor unit. • Do not install the unit in a humid, oily, or dusty location or in a location exposed to direct sunlight, water, or WARNING rain.
Page 53
- Check the installation site every 3 months and perform anti-corrosion treatment such as R-Pro CAUTION supplied by SAMSUNG (Code : MOK-220SA) or • Do not connect the drain hose to existing waste pipes commercial water repellent grease and wax, etc., as odors may arise.
Page 54
11. Installation Examples for installing one outdoor unit: Outdoor Unit: inch (mm) unit Outdoor Sea breeze unit 78.74 (2000) Outdoor unit Sea breeze 23.6 (150) (600) 11.8 (300) Outdoor Protection wall unit Examples for installing multiple outdoor units: Sea breeze Unit: inch (mm) Outdoor unit 23.6...
Page 55
11. Installation Indoor Unit Installation Attaching the mounting bracket to the wall Drilling the wall penetration 1 Determine the position of the hole through which the 1 Hold the mounting bracket against the wall at the piping bundle (consisting of power and communication selected installation position making sure that the cables, refrigerant pipes, and the drain hose) will pass.
Page 56
11. Installation Indoor Unit Installation 2 Use a standard 2-5-inch (65-mm) hole saw to drill one Connecting the power and communication cables hole at the selected location, at a 15° downward angle so that the drain hose will drain properly. installation manual supplied with the outdoor unit.
Page 57
11. Installation Indoor Unit Installation CAUTION • Connect the wires firmly so that wires cannot be pulledout. Loose wires can cause the connection to overheat. Each circular terminal must match the size of itscorresponding screw in the terminal block. CAUTION •...
Page 58
11. Installation Outdoor Unit Installation On the ground installation manual supplied with the outdoor unit. 1 Place the outdoor unit in the selected installation location, ensuring proper clearances and with the Mounting the outdoor unit arrow on top of the unit pointing away from the wall. 2 Clip the rubber feet to the tabs to minimize sound and To promote proper condensate draining, the vibration to the structure.
Page 59
11. Installation Outdoor Unit Installation On a wall WARNING • The unit must be properly secured to the wall. If the unit falls, it may result in crushing, electric shock, fire, or explosion that could cause death, severe personal injury, or property damage. 1 At the selected installation location attach the L-bracket to the wall as follows: - Install the bracket as close to the wall as possible.
Page 60
2020.05 Ver.1.5 Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677 Website : www.samsung.com, https://partnerhub.samsung.com Email : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.