  • Page 1 ® Helios Force/Safety Door Access Intercom Installation Manual Version 1.0.0 www.2n.cz  ...
  • Page 2 For the full wording of the Declaration of Conformity see the CD-ROM (if enclosed) or our website at www.2n.cz. The 2N TELEKOMUNIKACE a.s. is the holder of the ISO 9001:2009 certificate. All development, production and distribution processes of the company are managed by this standard and guarantee a high quality, technical level and professional aspect of all our products.
  • Page 3: Table Of Contents

    Content 1. Product Overview ........4 1.1 Product Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5  ...
  • Page 4: Product Overview

    Here is what you can find in this section: 1.1 Product Description 1.2 Upgrade 1.3 Components and Associated Products 1.4 Terms and Symbols ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 5: Product Description

    1.1 Product Description Basic Features ® Helios Force/Safety is a highly resistant and reliable door access intercom ® provided with a lot of useful above-standard functions. Helios Force/Safety work as a standard or emergency door access intercom for buildings, entrances to premises or garages, manufacturing halls, highways and so on.
  • Page 6: Upgrade

    1.2 Upgrade The manufacturer reserves the right to modify the product in order to improve its qualities. Version Changes – ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 7: Components And Associated Products

    No. 9152101-E No. 9151201-E No. 9151201K-E No. 9151204-E ® ® ® ® Helios Safety Helios Force Helios Force Helios Force 1 button 1 button 1 button with keypad 4 buttons ® Helios Force/Safety is designed for outdoor applications and requires no additional roof.
  • Page 8 Part No. 501303E Part No. 91341711E GSM gateway Analogue/VoIP gateway EasyGate Electric Locks Part No. 932070 Part No. 932080 Part No. 932090 BEFO 1211 12 V / 600 BEFO 1221 with BEFO 1211MBwith mechanical momentary pin blocking ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 9 Other Accesories Part No. 91341481E 12 V / 2 A adapter Note: AC power supply is not applicable. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 10: Terms And Symbols

    Warning Always abide by this information to prevent damage to the device. Caution Important information for system functionality. Useful information for quick and efficient functionality. Note Routines or advice for efficient use of the device. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 11: Description And Installation

    2. Description and Installation ® In this section we describe the Helios Force/Safety products and its installation. Here is what you can find in this section: 2.1 Before You Start 2.2 Mechanical Installation 2.3 Electric Installation 2.4 Button Tags – Insertion and Replacement ®...
  • Page 12: Before You Start

    × small bushing with nut × bushing plug, big size × bushing plugs, small size ® × 2N Helios Force / Safety Brief Manual × mounting template × × A5 transparent name plate foil × spare name tag ×...
  • Page 13: Mechanical Installation

    Wall mounting (concrete and steel structures, entry barrier columns, etc.) What You Need: ® Just your Helios Force/Safety unit (the frame is not applied) Flush mounting – classic bricks What You Need: A precisely cut hole or, optionally, the brick flush mounting box, Part No.
  • Page 14 Brick flush mounting box, Part No. 9151001 ® Helios Safety Mounting frame, Part No. 9152000 Flush mounting – plasterboard wall What You Need: Plasterboard flush mounting box, Part No. 9151002 ® Helios Safety Mounting frame, Part No. 9152000 ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 15: Common Mounting Principles

    Remember that dowels of poor quality may easily get loose and fall out of the wall! ® Stainless steel screws are used for the 2N Helios Force/Safety assembly. Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment!
  • Page 16 ® Select the Helios Force/Safety position with respect to the supply cables. Where the cables are installed inside a structure or wall, use the hole at the intercom bottom.
  • Page 17 Do not complete mounting until you have finished electrical installation – refer to Mounting Completion Flush Mounting – Thermally Insulated Wall Cut out the thermal insulation layer using the template (the same as for classic brick wall). ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 18 Flush Mounting – Hollow Bricks ® Suppose you intend to install your Helios Force/Safety unit into a wall made of hollow bricks. Note that the external side of the bricks gets damaged by cutting and the dowels cannot practically be fixed into the thin internal part of the bricks.
  • Page 19: Use Of Cable Bushings

    Use the plasterboard flush mounting box and follow the instructions included therein. Use of Cable Bushings ® The cable bushings included in the Helios Force/Safety delivery are designed for the following cables: Big bushing: for two cables of the diameter of 5–6 mm (UTP cable), or, upon insert replacement, for one thick cable/tube of the diameter of up to 14 mm.
  • Page 20 Pull the cable connector though the bushing body into the intercom and clip it into the motherboard connector. Move the sealing including the cover along the cable as far as the bushing body, or add a plug if necessary. Replace and tighten the nut. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 21: Electric Installation

    2.3 Electric Installation ® This subsection describes how to connect Helios Force/Safety to your PBX and how to connect supply voltage and the electric lock. PCB Connectors ® Figure below shows the lay-out of connectors on the Helios Force/Safety printe d circuit board (PCB).
  • Page 22 – except for the amplifier, ® button backlight and electric lock, if connected. Nevertheless, 2N Helios Force/Safety can work without these circuits too (amplifier is bypassed in this case).
  • Page 23: Electric Lock Connection

    ® Helios Force/Safety contains a solid-state switch, which is able to switch both AC and DC regardless of polarity. Make sure that the current and voltage values do not exceed limits (refer to the Technical Data) and that the technical parameters of the lock and power supply are compatible.
  • Page 24: Mounting Completion

    An incorrect mounting may compromise the intercom water tightness. Water leakage may damage the electronic part of the system. ® Stainless steel screws are used for the 2N Helios Force/Safety assembly. Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment! ®...
  • Page 25: Button Tags - Insertion And Replacement

    2.4 Button Tags – Insertion and Replacement Caution ® This feature is only for 2N Helios Force Tag Printing Every name plate includes a piece of foil, which can be written over manually, using a waterproof permanent marker. Note Always use waterproof foil (enclosed or other) for the tags. Never use...
  • Page 26: Programming And Use

    3. Programming and Use ® In this section we describe the basic and extending functions of the 2N Helios Force/Safety product. Here is what you can find in this section: 3.1 Programming 3.2 Full Parameter Chart ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 27: Programming

    (excluding passwords). Now you can enter new data – of variable meaning and length depending on the parameter selected (refer to the Full Parameter Chart). Finally, press again for confirmation. The intercom confirms the data saving. Repeat this procedure for each parameter. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 28: Programming Error

    The timeout can be prolonged – see the chart. To check programmed values : enter parameter number and listen the parameter value and press for return to the main menu. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 29 If you forget the service password, contact the manufacturer. The manufacturer can change your service password to 12345 remotely without altering any other parameter. Keyboard letters facilitate password remembering. For example, it is easier to remember a 9-letter word (e.g. crocodile) than a 9-digit number (276263453). ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 30: Full Parameter Chart

    1 above. Button 01 to 04 up to 16 Arrival/Departure blank digits password Button numbers 05–54: see note 1 above. The same as for Arrival/ Day/Night up to 16 blank Departure, identical for all password digits buttons ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 31 Telephone mode 0–1 disabled Tone dialling 0–1 during call disabled Microphone 0 = Maximum microphone 0–3 power-up level sensitivity Automatic 0–3 3 = Maximum response speed response speed Reception 15 = Maximum reception 0–15 volume volume ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 32 0,5 s ) incoming calls, an incorrect setting may result in the intercom not answering the call! Minimum long 10 = 1 5–100 pause time Maximum long 60 = 6 10–100 pause time ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 33 2 = identification (974) - loud 2 digits multiple number speaking dialling 4 = identification (974) - DTMF 5 = message as defined in par. (after confirmation by par. 976) 7 = confirming tone (after confirmation only) ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 34 ) Types 3 and 4 of Automatic Dialling without Confirmation differ from each other in how they process very short calls (a few seconds). Dialling type 4 regards a call as successful in all cases, type 3 only if the door was opened. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 35: Explanation Of Some Parameters

    Since the tone – pause difference is 500 − 250 = 250 ms, set parameter 944 to 300 ms, for example. Note Increase parameter 944 also when the intercom is placed in a hall or corridor with a large decay time. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 36: Function And Use

    4. Function and Use This section describes the basic and extending functions of the product. Here is what you can find in the section: 4.1 Function Description 4.2 Section for Advanced Users 4.3 Maintenance ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 37: Function Description

    Number Dialling mode is OFF. For this special mode refer to the Automatic Multiple Number Dialling section. Function Description – Numerical Keypad Models ® Helios Force model 9151201K-E is equipped with a numerical keypad. The keypad provides a number of functions:...
  • Page 38: Door Opening

    From Internal User's View (Survey of Functions) ® Calling to 2N Helios Force/Safety You call the appropriate extension and the intercom makes the call and gives a confirmation tone after two rings (or as pre-programmed). Now you can speak and control the switch, program the intercom (see later), and listen to what is going on outside and speak to the calling party if desired.
  • Page 39 The voice menu helps you considerably with programming the intercom. Having entered the programming mode, you can also alter any parameter and memory settings. Caution The above mentioned functions (except for calls to the intercom) require tone-dialling telephone set ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 40: Signals Overview

    UK, the U.S.A. (the so-called BTT tone) and in Canada. This new function does not require setting of any parameter. One of the tone components must be of 440 Hz. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 41 It is used in combination with automatic information systems, voice mailboxes, etc., which ask the calling party to select a service using tone dialling. This function, however, does not allow you to call destinations other than the pre-programmed ones. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 42 01…54 – the number that complies with the selected button (memory) is dialled after a timeout. – If an asterisk is pressed after number 01…54, the number is dialled immediately unless it is identical with the set password. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 43: Frequently Asked Questions About Keypad Function

    It is not recommended to use such passwords as 3333. This leads to a considerable wear and tear of one button and an unauthorised person may guess your password easily. It is ideal to employ all keys evenly, using several codes for different persons or groups. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 44 × … Yes if this function is programmed 1) This holds if DTMF is disabled during outgoing calls (the corresponding tone is transmitted in that case). 2) If pulse dialling is selected, it is possible to switch into tone dialling by ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 45 (but not vice versa!). ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 46: Section For Advanced Users

    Ringing tone, 10 rings are made Hangs up and dials the next number. (the count of rings is variable) These digits are interpreted as password beginning. Call extension or password beginning. Hang-up command. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 47 However, this may only decelerate automatic dialling (the busy tone may not be recognised, e.g.). Even if the intercom cannot identify the DTMF, the connection is established (yet for a shorter time). ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 48: Dtmf Control

    These commands do not work in the Automatic Multiple Number Dialling mode without Confirmation! The above-mentioned commands may not be accepted due to poor connection if sent during a message. To avoid this, press the button during the time of silence (between messages). ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 49: Survey Of Messages

    Dutch ..... Arrival/Departure, Day/Night Modes 2N® Helios Force / Safety can identify easily where to 'route' (switch) a call after a button is pressed. All you have to do is call the intercom and enter the following: I'm leaving: password...
  • Page 50 01 is 333. The family is leaving for holiday. They call the intercomand enter: A visitor presses the Johnsons' button – the intercom calls Mr. Johnson's mobile phone and, if unsuccessful, Mrs. Johnson's mobile phone. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 51: Maintenance

    The manufacturer reserves the right to modify the product in order to improve its qualities. ® Helios Force/Safety contains no environmentally harmful components. When the product's service life is exhausted and you would like to dispose of it please do so in accordance with applicable legal regulations ®...
  • Page 52 ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 53: Technical Parameters

    5. Technical Parameters ® In this section we describe the technical parameters of the 2N Helios Force/Safety product. Telephone Parameters ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 54 Switch – min. voltage: 9 V AC, DC Switch – max. current: 2 A AC, DC Backlight – rated voltage: 12 V Backlight – max. voltage: 14 V Backlight – current consumption: Up to 5 mA ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 55 Buttons Button design: ® Helios Force : 1 to 4 transparent, white backlit buttons with easily replaceable name tags ® Helios Safety One illuminated, stainless steel pushbutton Audio Microphone: 1 integrated microphone Amplifier: Optional – additional 0,5 W amplifier Physical Properties Cover: Robust aluminium cast product Working temperature: −25°C to +55°C...
  • Page 56: Supplementary Information

    6. Supplementary Information ® This section provides supplementary information on the Helios Force/Safety duct. Here is what you can find in this section: 6.1 Troubleshooting 6.2 Directives, Laws and Regulations 6.3 General Instructions and Cautions ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 57: Troubleshooting

    6.1 Troubleshooting For the most frequently asked questions refer to faq.2n.cz ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 58: Directives, Laws And Regulations

    6.2 Directives, Laws and Regulations Europe ® Helios Force/Safety conforms to the following directives and regulations: Directive 1999/5/EC of the European Parliament and of the Council, of 9 March 1999 – on radio equipment and telecommunications terminal equipment and the mutual...
  • Page 59: General Instructions And Cautions

    The manufacturer also assumes no responsibility for additional costs incurred by the consumer as a result of making calls using a line with an increased tariff. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 60: Electric Waste And Used Battery Pack Handling

    Make sure that the devices to be disposed of are complete. Do not throw battery packs into fire. Battery packs may not be taken into parts or short-circuited either. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 61 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Phone: +420 261 301 500, Fax: +420 261 301 599 E-mail: sales@2n.cz Web: www.2n.cz ® TELEKOMUNIKACE a.s., www.2n.cz...