Panasonic KX-TDA100 Installation Manual page 35

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

Calculation Example (KX-TDA200)
KX-T7600 series DPT
Other DPT
SLC16
MSLC16
VPS
Total
The total load figure is 96. As this is between 64 and 128, you should install the PSU-M. However, if you
expect expansion in the future, it may be better to install the PSU-L. There is no harm in installing a PSU
that is larger than is required for the current configuration.
Equipment Type
48 units
2 units
1 card
1 card
8 ports
1.4 Specifications
Load Figure
48
8
16
16
8
96