Hardware Installation Guidelines

CAUTION
WARNING!

Precautions

Before installing an AP 7161 model access point, verify the following grounding and lightning protection notes:
• The installation professional should be familiar with all grounding requirements and regional codes and ensure
that the access point and mounting asset are properly grounded. The grounding cable for an AP 7161 must be
at a minimum a #10 gauge wire cross section. The cable can be attached to the unit using one of the following
methods:
Loosen the grounding screw, insert the grounding cable into the hole below it, and tighten the screw.
Loosen the grounding screw, wind the grounding cable around it, and tighten the screw.
Attach a ring lug to the grounding cable and secure it to the unit using the grounding screw.
• To properly attach the grounding cable to the access point, refer to
• For Ethernet and lightning protection, it is recommended that a commercially available off-the-shelf Lightning
Protection Unit (LPU) be used on all shielded CAT5E Ethernet connections. The LPU should be rated for outdoor
use.
For the best possible protection, each access point requires an LPU be installed adjacent to the access point.
If there is a LAN connection to an indoor network, a second LPU is required at the cable entry point to the
building.
CAUTION
• Verify that the deployment environment has a continuous temperature range compatible with the operating
temperature range of the device.
All device wiring must comply with the National Electric Code (NEC) or regulations
and procedures defined by the regulatory bodies of the country or region where the
devices are being deployed. All local building and structure codes must be
observed.
Strictly observe the following safety precautions and warnings when installing an AP
7161 access point.
Lightning damage is not covered under the conditions of a standard Motorola
Solutions product warranty. When installed correctly, Lightning Protection
Units (LPUs) provide the best protection from the harmful effects of lightning.
Observe all regional and national codes that apply for lightning protection.
AP 7161 Access Point Installation Guide
AP 7161 Grounding Screw on page 18
.