Indoor unit for building application
Hide thumbs Also See for CITY MULTI PKFY-P-VBM-E:

Advertisement

Quick Links

Air-Conditioners For Building Application
INDOOR UNIT
PKFY-P·VBM-E

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimaanlage das Installationshandbuch gründlich durch-
lesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous as-
surer d'une utilisation correcte.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner
installeert.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire
acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il con-
dizionatore d'aria.
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΕΓΚΑΤΑΣΤΑΣΗΣ
Για ασφάλεια και σωστή χρήση, лαρακαλείστε διαβάσετε пρоσεχτικά αυτό το εγχειρίδιο εγκατάστασης пριν
αρχίσετε την εγκατάσταση της μονάδας κλιματισμού.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade
de ar condicionado.
MONTAJ ELKİTABI
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını monte etmeden önce bu
elkitabını dikkatle okuyunuz.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным
руководством по установке до выполнения установки кондиционера.
安装说明书
在安装空调机之前,请先通读此安装说明书,以便安全正确地使用。
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
安装人员适用
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Português
Türkçe
Русский
中文

Advertisement

loading

Summary of Contents for Mitsubishi Electric CITY MULTI PKFY-P-VBM-E

  • Page 1: Installation Manual

    Air-Conditioners For Building Application INDOOR UNIT PKFY-P·VBM-E INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Zum sicheren und ordnungsgemäßen Gebrauch der Klimaanlage das Installationshandbuch gründlich durch- lesen.
  • Page 2: Table Of Contents

    • Use the specifi ed cables for wiring. prevent the refrigerant concentration from exceeding the safety limit even if • Use only accessories authorized by Mitsubishi Electric and ask the dealer the refrigerant should leak. or an authorized technician to install them.
  • Page 3: Installing The Indoor Unit

    3. Installing the indoor unit (mm) 3.1. Installing the wall mounting fi xture (Fig. 3-1) 79.5 3.1.1. Setting the wall mounting fi xture and piping positions 109.5 Using the wall mounting fi xture, determine the unit’s installation position and the locations of the piping holes to be drilled. Warning: Before drilling a hole in the wall, you must consult the building contractor.
  • Page 4: Refrigerant Pipe And Drain Pipe

    3. Installing the indoor unit Lift the indoor unit by hooking the supporting piece (attached to the mount board) to the ribs on the back of the unit as shown. (Fig. 3-6) When piping work etc. is complete, replace the supporting piece on the mount board.
  • Page 5 4. Refrigerant pipe and drain pipe (mm) 4.2. Positioning refrigerant and drain piping Position of refrigerant and drain piping (Fig. 4-2) • The drain pipe can be cut midway to meet the on-site conditions. (Total length of fl exible hose) Gas pipe Liquid pipe Drain hose...
  • Page 6: Electrical Work

    5. Electrical work 5.1. Indoor unit (Fig. 5-1,5-2) Right side view (from CN90 1) Remove the front panel, then remove the corner box from the lower right corner of the indoor unit. 2) Remove the screw fi xing the electric parts cover and remove the cover. Claw 3) Connect the power cable and transmission cable to the terminal block.
  • Page 7: Test Run

    5. Electrical work 5.3. Setting addresses (Fig. 5-5) (Be sure to operate with the main power turned OFF.) • There are two types of rotary switch setting available: setting addresses 1 to 9 220V 240V CN43 and over 10, and setting branch numbers. Note: Please set the switch SW5 according to the power supply voltage.
  • Page 8 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is Low Voltage Directive 2006/95/EC based on the following Electromagnetic Compatibility Directive EU regulations: 89/336/ EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.