Mitsubishi Electric PKFY-P·VBM-E Operation Manual
Mitsubishi Electric PKFY-P·VBM-E Operation Manual

Mitsubishi Electric PKFY-P·VBM-E Operation Manual

Air-conditioners for building application indoor unit
Hide thumbs Also See for PKFY-P·VBM-E:

Advertisement

Air-Conditioners For Building Application
INDOOR UNIT
PKFY-P·VBM-E / PKFY-P·VHM-E
PCFY-P·VKM-E / PFFY-P·VKM-E
PMFY-P·VBM-E

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el fi nal antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΧΡΗΣΕΩΣ
Για ασφάλεια και σωστή χρήση, παρακαλείστε διαβάσετε προσεχτικά αυτό το εγχειρίδιο χρήσεως πριν θέσετε
σε λειτουργία τη μονάδα κλιματισμού.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a uni-
dade de ar condicionado.
Işletme Elkitabı
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını işletmeden önce bu
elkitabını dikkatle okuyunuz.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями, указанными в
данном руководстве по эксплуатации, тщательным образом до того, как приступать к использованию кондиционера.
操作说明书
在操作空调机之前,请全面阅读本操作说明书,以便安全和正确地使用本机。
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
ΓΙΑ ΤΟΝ ΧΡΗΣΤΗ
PARA O UTILIZADOR
KULLANICI İÇİN
ДЛЯ ПОЛЬЗОВАТЕЛЯ
用户适用(安装人员适用)
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Português
Türkçe
Русский
中文

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PKFY-P·VBM-E

  • Page 1: Operation Manual

    Air-Conditioners For Building Application INDOOR UNIT PKFY-P·VBM-E / PKFY-P·VHM-E PCFY-P·VKM-E / PFFY-P·VKM-E PMFY-P·VBM-E OPERATION MANUAL FOR USER English For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    Contents 1. Safety Precautions ................2 7. Other Functions ................11 2. Parts Names ..................3 8. Function Selection ................12 3. Screen Confi guration ................6 9. Emergency operation for wireless remote-controller ...... 16 4. Setting the Day of the Week and Time ..........6 10.
  • Page 3: Parts Names

    2. Parts Names Indoor Unit PKFY-P·VBM-E PKFY-P·VHM-E PCFY-P·VKM-E PMFY-P·VBM-E PFFY-P·VKM-E Fan speed 4 speed 3 speed+ Auto* 4 speed+ Auto* 4 speed 4 speed Steps 4 steps 5 steps 5 steps 4 steps 4 steps Vane Auto swing Louver Manual Manual Manual Manual...
  • Page 4: Operation Section

    2. Parts Names Wired Remote-Controller “Sensor” indication Day-of-Week Displayed when the remote controller Display Section sensor is used. Shows the current day of the week. For purposes of this explana- Time/Timer Display tion, all parts of the display are “Locked” indicator Shows the current time, unless the simple or Auto shown.
  • Page 5 2. Parts Names Wireless Remote-Controller Transmission area Transmission indicator Remote controller display Timer indicator * For explanation purposes, all of the items that appear in the display are shown. * All items are displayed when the Reset button is pressed. Operation areas ON/OFF button Set Temperature buttons...
  • Page 6: Screen Confi Guration

    3. Screen Confi guration <Screen Types> For details on setting the language for the remote controller display, refer Function Selection of remote controller Set Day/Time to section 8. Function Selection. The initial language setting is English. Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restrictions, etc.)
  • Page 7 5. Operation 5.2. Mode select Note: The number of available fan speeds depends on the type of unit Press the operation mode ( ) button and select the op- connected. Note also that some units do not provide an “Auto” eration mode setting.
  • Page 8: Timer

    5. Operation <[Manual] To Change the Airfl ow’s Left/Right Direction> Note: * The louver button 7 cannot be used. Available directions depend on the type of unit connected. Note • Stop the unit operation, hold the lever of the louver, also that some units do not provide an “Auto”...
  • Page 9 6. Timer 6.1.2. Simple Timer <Setting the Weekly Timer> 5. Press the appropriate Set Time button 1 as necessary to set the de- You can set the simple timer in any of three ways. sired time (at 5). • Start time only: * As you hold the button down, the time fi...
  • Page 10 6. Timer 7. After completing steps 3 to 6 above, press the Filter button 4 to Example 2: Start the timer with OFF time set earlier than ON time lock in the value. ON Setting : 5 hours Note: OFF Setting: 2 hours Your new settings will be cancelled if you press the Mode (Return) button 2 before pressing the Filter button 4.
  • Page 11: Other Functions

    6. Timer <Checking the Current Auto Off Timer Setting> 6.2. For Wireless Remote-controller Timer Setting 1. Be sure that the “Auto Off” is visible on the screen (at 1). 2. Hold down the Timer Menu button 2 for 3 seconds so that “Monitor” is indicated on the screen (at 4).
  • Page 12: Function Selection

    7. Other Functions 7.2. Error Codes indication ON lamp (Blinking) Error Code Unit No. If you have entered contact number to be called in the event of a problem, the screen displays this number. (You can set this up under Function Selection of remote controller. For information, refer to section 8.) If the ON lamp and error code are both blinking: This means that the air conditioner is out of order and operation has been stopped (and cannot resume).
  • Page 13 8. Function Selection [Function selection fl owchart] Normal display (Display when the air conditioner is not running) Hold down the button and press the button for 2 seconds. Setting language (English) Press the operation mode button. Hold down the button and press the button for 2 seconds.
  • Page 14 8. Function Selection [Detailed setting] [4]–3. Mode selection setting (1) Remote controller main/sub setting [4]–1. CHANGE LANGUAGE setting ON/OFF] button D. • To switch the setting, press the [ The language that appears on the dot display can be selected. 1 Main: The controller will be the main controller.
  • Page 15 8. Function Selection [Dot display table] Selecting language English German Spanish Russian Italian Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
  • Page 16: Emergency Operation For Wireless Remote-Controller

    9. Emergency Operation for Wireless Remote-controller When the remote-controller cannot be used When the batteries of the remote controller run out or the remote control- ler malfunctions, the emergency operation can be done using the emer- gency buttons. A DEFROST/STAND BY lamp B Operation lamp C Emergency operation switch (heating) D Emergency operation switch (cooling)
  • Page 17 10. Care and Cleaning PCFY-P·VKM-E PFFY-P·VKM-E 1 Open the intake grille. 2 Hold the knob on the fi lter then pull the fi lter up in the direction of an arrow. To replace the fi lter after cleaning, be sure to insert the fi...
  • Page 18: Trouble Shooting

    11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Clean the fi lter. (Airfl ow is reduced when the fi lter is dirty or clogged.) Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
  • Page 19 11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifi cations. The indoor operation sound level is affected by the acoustics of the par- ticular room as shown in the following table and will be higher than the noise specifi...
  • Page 20: Specifi Cations

    12. Specifi cations PCFY-P·VKM-E Series Model P100 P125 Power source (Voltage<V>/Frequency) <Hz> ~/N 220-230-240/50, 220/60 Capacity (Cooling/Heating) <kW> 4.5/5.0 7.1/8.0 11.2/12.5 14.0/16.0 Dimension (Height) <mm> Dimension (Width) <mm> 1280 1600 Dimension (Depth) <mm> Net weight <kg> Fan Airfl ow rate (Low-Middle2-Middle1-High) <m /min>...
  • Page 21 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN BG79U322H08 Printed in Japan...

Table of Contents