Appendix D How to Use PLC Function|
D.5.2 Output Commands
Commands
OUT
SET
RST
D.5.3 Timer and Counters
Commands
TMR
CNT
D.5.4 Main Control Commands
Commands
MC
MCR
D.5.5 Rising-edge/falling-edge Detection Commands of Contact
Commands
LDP
LDF
ANDP
ANDF
ORP
ORF
D-28
Drive coil
Action latched (ON)
Clear the contacts or the registers
16-bit timer
16-bit counter
Connect the common series connection
contacts
Disconnect the common series connection
contacts
Rising-edge detection operation starts
Falling-edge detection operation starts
Rising-edge detection series connection
Falling-edge detection series connection
Rising-edge detection parallel connection
Falling-edge detection parallel connection
Function
Function
Function
Function
Revision Jan. 2009, 06EE, SW--PW V1.12/CTL V2.12
Operands
Y, M
Y, M
Y, M, T, C, D
Operands
T-K or T-D
C-K or C-D
Operands
N0~N7
N0~N7
Operands
X, Y, M, T, C
X, Y, M, T, C
X, Y, M, T, C
X, Y, M, T, C
X, Y, M, T, C
X, Y, M, T, C