Operating instructions

for the system user
Heating system
With control unit for constant temperature operation
VITODENS 100
Please keep safe.
5592 521 GB
6/2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VITODENS 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Viessmann VITODENS 100

  • Page 1: Operating Instructions

    VIESMANN Operating instructions for the system user Heating system With control unit for constant temperature operation VITODENS 100 Please keep safe. 5592 521 GB 6/2006...
  • Page 2: For Your Safety

    Safety instructions For your safety Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained If you smell gas Danger Danger This symbol warns against the Escaping gas can lead to risk of injury. explosions which may result in serious injury.
  • Page 3 Safety instructions For your safety (cont.) In case of fire Ancillary components, spare and wearing parts Danger Fire creates the risk of burning Please note and explosions. Components which are not & Shut down the heating sys- tested with the heating system tem.
  • Page 4: Table Of Contents

    Index Index Introductory information Initial start-up ..................... Your system is preset at the factory ............. Certification details ..................General description ..................Where to find the controls Summary of controls and indicators ............& Opening the control unit ................& Control and display elements ..............&...
  • Page 5: Introductory Information

    All data is saved in case of power fail- Your heating system is therefore ure. ready for use. Certification details The Vitodens 100 is certified to com- The appliance classification is either ply with the requirements of the rele- or C depending upon whether...
  • Page 6 Introductory information General description (cont.) The output is automatically controlled according to demand (in both domes- tic hot water and central heating mode). Note that hot water is always given priority.
  • Page 7: Where To Find The Controls

    Where to find the controls Summary of controls and indicators Opening the control unit The controls and display elements are behind the hinged flap at the front. Control and display elements The control unit is preset at the factory for standard operation. Your heating system is therefore ready for use.
  • Page 8: Indicators On Display

    Where to find the controls Summary of controls and indicators (cont.) Indicators on display A Display value / fault code G Fault B Heating mode H System pressure (in conjunction C DHW heating with the display value) D Burner in operation K Service setting active (only for E Current burner output contractors)
  • Page 9: Start-Up/Shutdown

    Start-up/shutdown Starting the heating system The initial start-up and matching up of the control unit to local conditions and the structural characteristics of the building must be carried out by your heating contractor. We recommend you contact your local heating contractor if you are planning to start up a heating system that has not been used for a long period.
  • Page 10: Settings

    Settings Operating modes Your Vitodens can be operated in the "Heating" or "DHW" operating modes. Heating mode If a Vitotrol 100 room temperature If the setting on the room temperature controller is connected, it is used to control unit is inadequate for achiev- set the required room temperature.
  • Page 11: Hot Water (Combi Boiler Only)

    Settings Hot water (combi boiler only) Vitodens 100 with integral instantaneous water heater. Select the hot water temperature in accordance with your personal require- ments (e.g. for showering). Switching ON: Move rotary selector tw to the required hot water temperature.
  • Page 12: Hot Water (System Boiler Only)

    Settings Hot water (system boiler only) For operation with a separate DHW cylinder, set DHW temperature at DHW cylinder thermostat.
  • Page 13: Displays

    Displays Heating water temperature and system pressure Checking the heating water tem- perature The heating water temperature appears on the display at all times during operation. Checking the system pressure 1. Turn both rotary selectors tr and tw anticlockwise as far as possi- ble 9 (turn selector tr only for system boiler).
  • Page 14: Switch Off

    Switch OFF Switching the Vitodens OFF with frost protection If you do not wish to use your boiler for several days you can switch the unit off. Turn both rotary selectors to 9. Frost protection is now active for the boiler.
  • Page 15: What To Do If

    Note: Care must be taken to ensure the fill valve is not left on. Viessmann Ltd. will not be liable for incorrect use of the filling loop; if in doubt contact your heating engineer.
  • Page 16: Fault Indicator On Display

    What to do if... System characteristics (cont.) What to do if ... Cause Remedy ... the heating system System controls includ- Switch ON system con- does not start ing room thermostats trols to create demand. not calling for heat..the burner does not Control fault Read off the fault codes ignite, display shows...
  • Page 17: Repairs

    Repairs Cleaning The appliance casing can be cleaned using a damp cloth and a mild deter- gent. Do not use abrasive cleaners. Inspection and maintenance To ensure continued efficient opera- tion of the appliance, it is recom- mended that it is checked and serviced as necessary at regular intervals.
  • Page 18: Energy Saving Tips

    Energy saving tips Energy saving tips Along with using a modern heating system, you can save additional energy by your own actions. The following steps will help you with this: & Correct ventilation/airing. Briefly open windows A fully and at the same time close thermostatic valves B.
  • Page 19: Keyword Index

    Keyword index Keyword index Cleaning Maintenance ........
  • Page 20 Your contact Contact your local heating contractor if you have any questions regarding the maintenance and repair of your heating system. You may, for example, find local heating contractors on the internet under www.viessmann.de. Viessmann Werke GmbH&Co KG Viessmann Limited...

Table of Contents