Item
Feed
1. Set documents on the Hopper.
2. Click "Feed" on the main menu.
3. Set "Test Mode" and "Test Condition" depending on each
scanning condition.
Note:
Operation "Imprinter" is available only when the
optional Imprinter is installed.
4. Click "START" on the "Feed" dialog box to start feeding
documents.
5. Click "STOP" on the "Feed" dialog box to stop the test.
6. Click "Close" to return to the main menu.
Sleep Mode
1. Click "Sleep Mode" on the main menu.
2. Click "START" on the "Sleep Mode" dialog box to enter the
sleep mode.
3. Click "STOP" to return from the sleep mode.
4. Click "Close" to return to the main menu.
CCD Level
1. Click "CCD Level" on the main menu.
2. Reverse the Reference Plate (F) and Reference Plate (B) to
white.
3. Set "Gain" of the Front and Back sides on the "CCD Level"
dialog box.
4. Click "START" on the "CCD Level" dialog box to start
the CCD Level Test.
5. Check whether the peak level is within specifications.
(See Remarks.)
6. Click "STOP" to finish this test.
7. Click "Close" to return to the main menu.