TK-290
3-2. Channel Setting Mode
Set data for each channel while in this mode. After first
entering Self programming mode, select the "CHAN" display
with [Top 1] [Top 2] and press [PTT] to set Channel Setting
mode. Once in Channel Setting mode, select the group that
needs setting with the [Top 1] [Top 2] keys and press [PTT].
Next select the channel for setting with the [Top 1] [Top 2]
keys and press [PTT]. The setting items and setting data will
then appear so reset the data with the [Top 1] [Top 2] keys
and press [PTT]. When finished, the display shifts to the
next setting item. After finished setting all items press
[PTT] to return to Group selection. Changes in the fre-
quency CH steps and the QT/DQT steps can be made in
[Side 1].
No.
Function name
Select
Group/Channel
1
RX frequency
2
RX signalling
3
TX frequency
4
TX signalling
5
Option signalling
6
DEL/ADD
7
Wide/Narrow
8
PTT ID
9
TX power
10
Busy channel lockout BCL OFF
11
Beat shift
• Operation
1. Select the setting value with the [Top 1] [Top 2] keys.
2. Press the [PTT] and the selected value is backed up and
operation shifts to the next item for setting.
3. Press [Side 2] on the Group selection screen in order to
return to Self programming mode.
12
REALIGNMENT
Display
Remarks
1.–1 during
1–160~160–1
group selection
1–1. during
channel selection
R150.0125
Receive frequency
(Dot on right edge is
lit up during 6.25kHz
steps)
RX 023N
Receive QT/DQT
(Dot on right edge is
lit up during 1 step
changes)
T150.0125
Transmit frequency
(Dot on right edge is
lit up during 6.25kHz
steps)
TX 250.3
Transmit QT/DQT
(Dot on right edge is
lit up during 1 step
changes)
2ToneA
OFF, DTMF, 2ToneA,
2ToneB, 2ToneC
D/A ADD
Delete, Add
WIDE
Wide. Narrow
ID OFF
OFF, ON
POW HI
High, Low
OFF, ON
SFT OFF
OFF, ON
• Note
1. Different sample displays are shown.
2. Setting item No.s are displayed with a 7-segment 2-digit
figure on the LCD.
3. Self programming mode cannot be set when set to
Disaable with the FPU.
4. A red LED lights up during TX frequency and TX signal-
ling.
5. Press [Orange] on the TX, RX frequencies setting screen
in order to clear in the channel frequencies data.
6. Press [Orange] on the signalling setting screen in order to
change or off the signalling function.
7. Flipping [Toggle] to the right during setting of RX, TX fre-
quencies and performing Up/Down operation allows fre-
quencies to be changed in MHz steps.
8. The RX and TX frequencies can be entered with the num-
ber pad keys.
• Flow Chart
Self programming mode
[Top 1] [Top 2]
Channel setting mode
[PTT]
Group selection
[Side 2]
[PTT]
Channel selection
[Side 2]
[PTT]
1. RX frequency
[Side 2]
[PTT]
2. RX signalling
[Side 2]
[PTT]
3. TX frequency
[Side 2]
[PTT]
4. TX signalling
[Side 2]
[PTT]
5. Option signalling
[Side 2]
[PTT]
6. Scan Delete/Add
[Side 2]
[PTT]
7. Wide/Narrow
[Side 2]
[PTT]
8. PTT ID on/off
[Side 2]
[PTT]
9. TX power Hi/Low
[Side 2]
[PTT]
10. Busy channel lockout on/off
[Side 2]
[PTT]
11. Beat shift on/off
[Side 2]
[PTT]
[Side 2]
Orange
Orange
OFF
QT
Orange
Orange
DQT I
DQT N
Orange
Orange
Orange
OFF
QT
Orange
Orange
DQT I
DQT N
Orange

Hide quick links: