Removing The Glove Compartment - APRILIA pegaso 650 i.e. Service Manual

Hide thumbs Also See for pegaso 650 i.e.:
Table of Contents

Advertisement

CHASSIS

7.1.32 REMOVING THE GLOVE COMPARTMENT

Carefully read 0.5.1 (PRECAUTIONS AND GENERAL
INFORMATIONS).
N
Remove the electronic unit, see 7.1.10 (REMOVING
THE ELECTRONIC UNIT).
N
Remove the number plate holder, see 7.1.31 (REMOV-
ING THE NUMBER PLATE HOLDER).
a
CAUTION
Take note of the layout of the electric cables, in order
to be able to position them correctly upon reassem-
bly.
N
Withdraw the following parts from their seats:
– injection relay (1);
– main fuse carrier (2);
– fall sensor (3).
N
Unscrew and remove the two screws (4), taking the
nuts.
Rear air filter casing screw driving torque: 10 Nm (1.0
kgm).
a
CAUTION
When reassembling, make sure the electric compo-
nents and relevant wiring are refitted correctly.
N
Unscrew and remove the two screws (5), taking the
bushes and if necessary the rubber element.
Glove compartment side screw driving torque: 6 Nm
(0.6 kgm).
N
Working on the lower part with a socket spanner, un-
screw and remove the screw (6), take the bush and if
necessary the rubber element.
Glove compartment lower screw driving torque: 7 Nm
(0.7 kgm).
N
Lower the glove compartment (7) and remove it, with-
drawing it from behind.
7
- 26
- 00
Pegaso 650 I.E.